Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLENWOOD ENERGY OF OXFORD

Discrimination inspection · Safety discipline

On , OSHA opened a discrimination safety inspection of GLENWOOD ENERGY OF OXFORD in 6351 FAIRFIELD ROAD, OXFORD, OH 45056 (NAICS 221210). OSHA activity number 348890765.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glenwood Energy of Oxford — free Get an email when a new federal OSHA severe-injury report for Glenwood Energy of Oxford is published. One employer, no account, unsubscribe in one click.
Site address
6351 FAIRFIELD ROAD
City
OXFORD
State
OH
ZIP
45056
Mailing
5181 COLLEGE CORNER PIKE, OXFORD, OH 45056
Inspection type
Discrimination (N)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221210
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2026
Penalty
Initial $2,412 · Current $0 Reduced
29 CFR  1926.651(k)(1): Inspections.  Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.  a) On or before April 20, 2026, the employer failed to ensure that adequate daily inspections of the excavation were completed prior to and during the workday while performing excavation work to expose gas utilities and insert trench boxes, exposing employees to potential cave-in protection in that the boxes were set more than two feet below the top of the excavation a trench greater than 5 feet deep.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2412

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2026
Penalty
Initial $2,412 · Current $0 Reduced
29 CFR 1926.652(a)(1): Protection of employees in excavations. Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: 1926.652(a)(1)(i): Excavations are made entirely in stable rock; or 1926.652(a)(1)(ii): Excavations are less than 5 feet (1.52 m) in depth and examination of the ground by a competent person provides no indication of a potential cave-in.   a) On or about April 20, 2026, the employer failed to ensure that a trench box or an alternative protection system was in proper place prior to employees working in the 5 foot deep excavation in that the trench boxes were set approximately two feet below the top of the excavation, resulting in employees being exposed to cave-in hazards while working on gas line repairs near a public roadway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2412

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348890765.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.