Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STELLAR PRECISION COMPONENTS, LTD.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STELLAR PRECISION COMPONENTS, LTD. in 1201 RANKIN AVENUE, JEANNETTE, PA 15644 (NAICS 332710). OSHA activity number 348927898.

Watch Stellar Precision Components, LTD. — free Get an email when a new federal OSHA severe-injury report for Stellar Precision Components, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
1201 RANKIN AVENUE
City
JEANNETTE
State
PA
ZIP
15644
Mailing
1201 RANKIN AVENUE, JEANNETTE, PA 15644
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332710
Employees
55
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972 · Current $3972
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  At the facility, on or about May 7, 2026 - A written respiratory protection program was not established and implemented when employees were required to wear a respirator.  Employees were required to wear a 3M half-mask respirator when operating the blasting cabinet.
Recent events (1)
  • — Z (S) $3972

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a)  At the facility on or about May 7, 2026 - Medical evaluations were not provided to employees to determine their ability to use a respirator.  Employees are required to wear a  3M half-mask respirator when using the blasting cabinet.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   a)  At the facility, on or about May 7, 2026 -  Employees were not provided with a qualitative fit test (QLFT) or quantitative fit test (QNFT) prior to donning a tight-fitting respirator.  Employees were required to wear a 3M half-mask respirator when using the blasting cabinet.
Recent events (1)
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k): The employer did not provide effective training which did not occur annually and/or more often if necessary:  a)  At the facility, on or about May 7, 2026 - Employees were not provided with effective respiratory protection training when required to wear a respirator.  Employees were required to wear a 3M half-mask respirator when operating the blasting cabinet.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348927898.