TAMPA, FL —
OSHA Inspection: ARC ROOFING AND SERVICES INC
Discrimination inspection · Safety discipline
At a glance
On , OSHA opened a discrimination safety inspection of ARC ROOFING AND SERVICES INC in 4002 W WATERS AVE, TAMPA, FL 33614 (NAICS 238160). OSHA activity number 348951419.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARC ROOFING AND SERVICES INC
- Site address
- 4002 W WATERS AVE
- City
- TAMPA
- State
- FL
- ZIP
- 33614
- Mailing
- 7621 CROTON AVE, TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Discrimination (N)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B10
- Issued
- May 29, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems: (a) On or about May 21, 2026, at the job site located at 4002 W Waters Ave, Tampa, Florida; employees were exposed to an approximately 9.6 foot fall hazard while conducting roofing activities such as laying drying-in on a 4 in 12 pitched (vertical to horizontal) roof, in that, fall protection was not utilized.
Recent events (2)
- — I (S) $2383.2
- — Z (S) $3972
1926.1053 B01
- Issued
- May 29, 2026
- Penalty
- Initial $2,838 · Current $1,703 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about May 21, 2026, at the job site located at 4002 W Waters Ave, Tampa, Florida; employees involved in roof work were exposed to an approximately 11.4-foot fall hazard, in that, the multi-position ladders were not extended 3 feet above the landing surface of the roof.
Recent events (2)
- — I (S) $1702.8
- — Z (S) $2838
1926.503 B01
- Issued
- May 29, 2026
- Abate by
- Jun 25, 2026
- Penalty
- Initial $319 · Current $191 Reduced
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) On or about May 21, 2026, at the job site located at 4002 W Waters Ave, Tampa, Florida; employees were exposed to an approximately 9.6 foot fall hazard while removing roof materials on a 4 in 12 pitched (vertical to horizontal) roof, in that, fall protection training was not certified.
Recent events (2)
- — I (O) $191.4
- — Z (O) $319
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348951419.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.