STAMFORD, CT ·
OSHA Inspection: GABRIEL VELAZQUEZ CHEN CONTRACTOR LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GABRIEL VELAZQUEZ CHEN CONTRACTOR LLC in 115 BERRIAN ROAD, STAMFORD, CT 06905 (NAICS 236118). OSHA activity number 348959123.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GABRIEL VELAZQUEZ CHEN CONTRACTOR LLC
- Site address
- 115 BERRIAN ROAD
- City
- STAMFORD
- State
- CT
- ZIP
- 06905
- Mailing
- 518 BROOKS STREET, #2, BRIDGEPORT, CT 06608
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 8
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 18, 2026
- Abate by
- Jul 24, 2026
- Penalty
- Initial $2,270 · Current $2,270
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. Located at 115 Berrian Road, Stamford, CT 06905: On or about May 27, 2026, the employer did not ensure that employees who were required to use pneumatic nail guns to install asphalt roofing shingles were provided with and required to wear eye protection, which exposed them to potential impalement hazards.
Recent events (1)
- · Z (S) $2270
1926.501 B13
- Issued
- Jun 18, 2026
- Abate by
- Jul 24, 2026
- Penalty
- Initial $3,972 · Current $3,972
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Located at 115 Berrian Road, Stamford, CT 06905: On or about May 27, 2026, the employer did not ensure that employees performing a residential roof tear-off and replacement were protected from a fall hazard of approximately 10' by the use of guardrails, safety nets, or personal fall arrest systems.
Recent events (1)
- · Z (S) $3972
1926.503 A01
- Issued
- Jun 18, 2026
- Abate by
- Jul 24, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. Located at 115 Berrian Road, Stamford, CT 06905: On or about May 27, 2026, the employer did not maintain a training program for employees to recognize and mitigate fall hazards, exposing employees to a fall hazard of approximately 10' on a residential roofing project.
Recent events (1)
- · Z (S) $0
1926.1053 B01
- Issued
- Jun 18, 2026
- Abate by
- Jul 24, 2026
- Penalty
- Initial $2,838 · Current $2,838
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. Located at 115 Berrian Road, Stamford, CT 06905: On or about May 27, 2026, the employer did not ensure that the approximately 11' ladder used to access and egress a roof had its side rails extended at least 3' beyond the upper landing surface of the roof, which exposed employees to a fall hazard of approximately 10'.
Recent events (1)
- · Z (S) $2838
More inspections in this industry (NAICS 236118)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348959123.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.