SOMERSET, WI ·
OSHA Inspection: J BUILDING LEGACY LLC
Unprogrammed Emphasis inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Emphasis safety inspection of J BUILDING LEGACY LLC in 837 SUTHERLAND ST., SOMERSET, WI 54025 (NAICS 238170). OSHA activity number 348961392.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J BUILDING LEGACY LLC
- Site address
- 837 SUTHERLAND ST.
- City
- SOMERSET
- State
- WI
- ZIP
- 54025
- Mailing
- 1411 18TH AVE. NE, MINNEAPOLIS, MN 55418
What kind of inspection was it?
- Inspection type
- Unprogrammed Emphasis (N)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Jun 8, 2026
- Abate by
- Jul 8, 2026
- Penalty
- Initial $3,972 · Current $3,972
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): (a) Throughout the jobsite; On or about May 27, 2026, the employer did not conduct frequent and regular inspections of the job site to identify and correct hazards associated with scaffold and portable ladder use.
Recent events (1)
- · Z (S) $3972
1926.451 G04 I
- Issued
- Jun 8, 2026
- Abate by
- Jul 8, 2026
- Penalty
- Initial $3,972 · Current $3,972
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: (a) Single-family home exterior, east side; On or about May 27, 2026, an employee working from a pump jack scaffold system to install siding panels and perform other exterior construction activities was not protected from falling from heights up to approximately 19 feet 4 inches above ground-level as the scaffold system was not equipped with a mid-rail, screen or mesh along the length of the work platform, end stops were not in place, and alternative fall protection measures were not in use.
Recent events (1)
- · Z (S) $3972
1926.452 J02
- Issued
- Jun 8, 2026
- Abate by
- Jul 8, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: (a) Single-family home exterior, east side; On or about May 27, 2026, an employee working from a pump jack scaffold system to install siding panels and perform other exterior construction activities at heights up to approximately 19 feet 4 inches above ground-level was exposed to fall and structural instability hazards associated with an improperly secured work platform, in that the vertical poles supporting the system were not provided with the required bottom braces to prevent swaying or displacement, creating the potential for the scaffold to shift or collapse during use.
Recent events (1)
- · Z (S) $0
1926.454 A
- Issued
- Jun 8, 2026
- Abate by
- Jul 8, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: (a) Single-family home exterior, east side; On or about May 27, 2026, an employee working from a pump jack scaffold system to install siding panels and perform other exterior construction activities had not been trained by a qualified person to recognize the hazards associated with the scaffold, including but not limited to, fall hazards of up to approximately 19 feet 4 inches above ground-level due to the lack of a mid-rail and end stops, and scaffold instability due to the lack of bottom bracing.
Recent events (1)
- · Z (S) $0
1926.1053 B01
- Issued
- Jun 8, 2026
- Penalty
- Initial $2,270 · Current $2,270
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Single-family home exterior, east side; On or about May 27, 2026, a Mighty Multi brand model MMHL-22 multi-position aluminum ladder, configured as an extension ladder and used to access and egress a pump jack scaffold system, was not set-up with the side rails extending at least three feet above the upper landing surface and/or was not secured from displacement.
Recent events (1)
- · Z (S) $2270
More inspections at J Building Legacy LLC
View J Building Legacy LLC's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348961392.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.