KINGSTON, PA ·
OSHA Inspection: OSTRANDER STEEL CO INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OSTRANDER STEEL CO INC in REAR 181 PRINGLE STREET, KINGSTON, PA 18704 (NAICS 000000). OSHA activity number 629196.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSTRANDER STEEL CO INC
- Site address
- REAR 181 PRINGLE STREET
- City
- KINGSTON
- State
- PA
- ZIP
- 18704
- Mailing
- P.O. BOX 1134, KINGSTON, PA 18704
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3441
- Employees
- 8
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
- Penalty
- Initial $240 · Current $120 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that: foot pedal mechanism(s) on machinery were not protected or were inadequately protected to prevent unintended operations from falling or moving objects or by accidental stepping onto the pedals: a) The foot treadle (front and sides of shear) was not guarded on the Hill and Jones Metal Shear located in the new bilding new the east wall, February 1, 1988. AMONG OTHER FEASIBLE AND ACCEPTABLE METHODS TO CORRECT THIS HAZARD WOULD BE: 1) Install a rigid metal guard over and above treadle 2) Install 2 hand tripping device with magnetic dies 3) Install Gate-A or fixed shields to ram 4) Install pullbacks/restraints 5) Install electronic sensing device
Recent events (2)
- · I (S) $120.00
- · Z (S) $240.00
1910.22 A02
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
- Penalty
- Initial $360 · Current $180 Reduced
Recent events (2)
- · I (S) $180.00
- · Z (S) $360.00
1910.212 A03 II
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
- Penalty
- Initial $240 · Current $120 Reduced
Recent events (2)
- · I (S) $120.00
- · Z (S) $240.00
1910.213 I01
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
- Penalty
- Initial $240 · Current $120 Reduced
Recent events (2)
- · I (S) $120.00
- · Z (S) $240.00
1910.219 B01
- Issued
- Mar 3, 1988
- Abate by
- Mar 8, 1988
- Penalty
- Initial $240 · Current $120 Reduced
Recent events (2)
- · I (S) $120.00
- · Z (S) $240.00
1910.303 G02 I
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
- Penalty
- Initial $120 · Current $60 Reduced
Recent events (2)
- · I (S) $60.00
- · Z (S) $120.00
1910.304 A02
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
- Penalty
- Initial $120 · Current $60 Reduced
Recent events (2)
- · I (S) $60.00
- · Z (S) $120.00
1910.305 E01
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
- Penalty
- Initial $300 · Current $150 Reduced
Recent events (2)
- · I (S) $150.00
- · Z (S) $300.00
1904.5 A
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
- Penalty
- Initial $60 · Current $30 Reduced
Recent events (2)
- · I (O) $30.00
- · Z (O) $60.00
1910.215 B09
- Issued
- Mar 3, 1988
- Abate by
- Mar 13, 1988
1910.219 E03 I
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
1910.303 F
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
1910.304 F04
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
1910.305 G01 III
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
1910.305 G02 III
- Issued
- Mar 3, 1988
- Abate by
- Mar 18, 1988
1910.1200 E01
- Issued
- Mar 3, 1988
- Abate by
- Apr 2, 1988
More inspections at Ostrander Steel CO INC
View Ostrander Steel CO INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA's own view of this case can be found through its Establishment Search.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.