U.S. TSUBAKI POWER TRANSMISSION, LLC

Event
Amputated, Amputation, Finger, Fingertip, Mechanical, Mechanical Power Press, Power Press, Press
NAICS
332999
Inspection type
Referral
Activity number
#345364020
Employer profile
U.S. TSUBAKI POWER TRANSMISSION, LLC
Summary number
221363195
Report ID
0112600

Event description

Employee sustains fingertip amputation while operating mecha

Investigation abstract

At 9:45 a.m. on June 11, 2021, Employee #1 was operating a mechanical power hospitalization. press to press chain links. The machine guarding and safety devices designed to prevent operator injury were deficient. The two-hand trip control allowed hand exposure during operation, the light curtains did not prevent access to the danger zone, and the automatic guard failed to prevent the operator from reaching around into the hazard area. The press's safety system and operational programming allowed a delayed but automatic cycling of the ram after the trip was triggered and all safety devices sent a safe signal back to the computer. The employee sustained a fingertip amputation and was treated without

Victim

  1. #1 Non-hospitalized injury Age 36 M