OSHA Accident Investigation · Summary #221385644
ARMORMAX REFRACTORIES, INC.
EDINBURG, PA·
Event description
Employee fractures foot while removing preheater lid
Investigation abstract
At 9:45 a.m. on July 16, 2021, Employee #1, a coworker, and a Foreman were removing a burned block from a preheater lid to replace refractory insulation. The preheater lid weighed approximately 2,500 pounds and measured roughly 12 by 14 feet. The Foreman attached the burner block to an overhead double-girder bridge crane via a nylon sling. While the foreman was pulling the burner block with the crane, Employee #1 walked around the cover using a pry bar to loosen the block. Unaware that the lid had lifted off the floor, Employee #1's foot was positioned under the edge when the cover fell, fracturing the first, second, and third metatarsals of his left foot. Employee #1 was hospitalized.
Victim
-
#1 Hospitalized Age 36 M
- Event type
- 1
- Occupation code
- 889