Struck by falling object or equipment, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at Hubbell Power Systems, Inc, 8100 Churchill Avenue, LEEDS, ALABAMA 35094
on , Fractures, affecting the hand(s), except finger(s).
Watch Hubbell Power Systems, Inc for freeGet an email when a new federal OSHA severe-injury report for Hubbell Power Systems, Inc is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was inserting the final bolt to install a 1,000-pound electrical substation switch on a metal frame. The switch was supported by a magnetic lifting device, which released the switch; it dropped about 2 inches and pinched the employee's left hand against the metal frame. The employee suffered injuries requiring surgery: two broken bones in the hand and lacerations to the index finger and thumb.