ANNISTON, ALABAMA·
Multimetco, Inc.
Direct exposure to electricity, unspecified · Second degree electrical burns
At a glance
Federal OSHA recorded a severe workplace injury at Multimetco, Inc., 1610 Frank Akers Road, ANNISTON, ALABAMA 36207 on , Second degree electrical burns, affecting the nonclassifiable.
Watch Multimetco, Inc. for free
Get an email when a new federal OSHA severe-injury report for Multimetco, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was changing a circuit breaker fuse when an arc flash occurred. The employee was hospitalized with second degree burns.
More severe injuries at Multimetco, Inc.
Apr 26, 2022
ANNISTON, ALABAMA · Compressed or pinched by shifting objects or equipment
Oct 7, 2019
ANNISTON, ALABAMA · Caught in running equipment or machinery during regular operation
Sep 28, 2017
ANNISTON, ALABAMA · Struck against moving part of machinery or equipment
View Multimetco, Inc.'s full OSHA safety record →
Similar incidents · Same event type
Dec 27, 2023
Amentum Spaceport LLC · KENNEDY SPACE CENTER, FLORIDA
Dec 27, 2023
Bob Woodall Air Care Systems, Inc. · DOTHAN, ALABAMA
Dec 21, 2023
Lankenau Medical Center - Main Line Health · WYNNEWOOD, PENNSYLVANIA
Dec 11, 2023
Marsh Bellofram Corporation · NEWELL, WEST VIRGINIA
Dec 7, 2023
Heart Utilities of Jacksonville, Inc. · JACKSONVILLE, FLORIDA
More severe injuries in this industry (NAICS 331492)
Nov 3, 2025
Doe Run Company · VIBURNUM, MISSOURI
Aug 20, 2025
The Perryman Company · COAL CENTER, PENNSYLVANIA
Jul 1, 2025
Envirofocus Technologies, LLC · TAMPA, FLORIDA
Jun 25, 2025
Ecobat Resources New York, LLC · MIDDLETOWN, NEW YORK
May 14, 2025
Befesa Zinc US Inc. · CHICAGO, ILLINOIS
More severe injuries in ALABAMA