Trane U.S., Inc.

Other fall to lower level 6 to 10 feet · Fractures and burns

Federal OSHA recorded a severe workplace injury at Trane U.S., Inc., 1255 Vandenberg Dr Ste 138, LITTLE ROCK AIR FORCE BASE, ARKANSAS 72099 on , Fractures and burns, affecting the multiple body parts, n.e.c..

Watch Trane U.S., Inc. for free Get an email when a new federal OSHA severe-injury report for Trane U.S., Inc. is published. One employer, no account, unsubscribe in one click.

On July 8, 2022 at 9:00 a.m., an employee was removing a flow meter located approximately 8.5 feet off the ground on a heated water system. The building was almost complete, so the heating and chilled water systems were operational. The employee was standing on the second rung from the bottom of the 6-foot A-frame ladder that was placed on a 6-foot concrete pad in the locked position. When the meter probe was removed, 180 F water under pressure struck the employee, causing him to fall backward off the ladder and resulting in a fractured ankle and hot water burns to both arms and his back.

Hospitalized Multiple body parts, n.e.c. Step ladders

View Trane U.S., Inc.'s full OSHA safety record →