105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Gallardo Roofing LLC

Fall to lower level resulting from exposure or contact 6 to 30 feet · Traumatic injuries or exposures unspecified

An employee went up on the roof using a ladder on the front side of the home and walked over the peak to observe the status of the roof being completed. The back side of the home was in the shade and had a thin patch of ice or frost that caused the employee to slide down the backside of the home and fall approximately 15 feet 9 Inches, resulting in injury that required hospitalization.

Hospitalized Part of body unspecified Roof surface

Buckeye Surface Maintenance

An employee was operating an asphalt grinding machine when a branch got in the way of the machine. He crawled on top of the machine to cut the branch but it snapped back and knocked him off the equipment. He fell approximately 10-12 feet to the ground below, resulting in fractures to both wrists and forearms, and a left knee fracture.

Rough & Ready of Central Florida Inc

A temporary employee was on a ladder while cutting conduit on a new building using a reciprocating saw. They sustained an electrical shock from a live electrical cable. The employee fell backward approximately 6 feet to the ground, resulting in hospitalization with a fractured heel that required surgery.

RIGGINS-MORELAND ENGINEERING INC.

An employee was working on the ninth position of a 12-foot ladder, installing a new light fixture in an existing building. The employee sustained an electrical shock, lost his balance on the ladder, and fell. He sustained a fracture of the lower back and bruises on his hand and foot. The fracture required surgery.

Industrial Fabrics, Inc.

At approximately 10:00 AM, employees were conducting asphalt loading operations. While securing a hose atop a truck, an employee encountered a malfunction involving a plugged hose. Pressure built up within the hose and suddenly released, causing the hose to fly off the truck. The hose contacted two employees and both employees fell approximately 7 feet. Employee 1 was on top of the truck and sustained three fractured ribs and a head contusion. Employee 1 was hospitalized. Employee 2 was climbing a ladder on the truck and sustained a fractured right leg. Employee 2 was not hospitalized.

Sentry Electric, Inc. of Central Florida

An employee was working from a ladder, installing light fixtures. The employee was shocked and fell from the ladder to the floor about 6 feet below, striking their head and back. The employee was hospitalized with a laceration to the head and broken vertebrae.