COMPCO Industries Inc.

Caught, entangled in running powered equipment normal operation · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at COMPCO Industries Inc., 400 W. RAILROAD ST., SUITE 2, COLUMBIANA, OHIO 44408 on , Amputations, avulsions, enucleations unspecified, affecting the finger or thumb tip(s), nail(s).

Watch Compco Industries Inc. for free Get an email when a new federal OSHA severe-injury report for Compco Industries Inc. is published. One employer, no account, unsubscribe in one click.

An employee was positioning a 2" diameter pipe in a pneumatic vise. The vise pinched the employee's right index finger partially amputating the fingertip.

Amputation Finger or thumb tip(s), nail(s) Vises, clamps