Struck by dislodged or detached object(s) · Multiple severe wounds and internal injuries
Final narrative
On August 12, 2024, an employee had an armature in a press and was pressing a shaft out of a motor. The press pushed the tool (a 1.5 inch in diameter metal steel rod with a cup that goes on top of the shaft) and it shot out and struck the employee's chest. The employee sustained eight fractured ribs and a perforated liver, resulting in hospitalization and surgery.
Similar incidents · Same event type
BLYTHEVILLE, ARKANSAS—
NATIONAL MILL MAINTENANCE, LLC
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
PILOT POINT, TEXAS—
C. Miller Drilling Inc
A service crew was pulling a pump and motor from a well. After breaking a joint of pipe loose from another joint, an employee grabbed the chain tongs to prevent the pipe from spinning in the well, so the crew could continue taking it apart. The bolt that attaches the chain to the handle of the chain tongs broke, causing the chain to swing around and strike the employee's lower right leg. The chain severely punctured his leg and fractured his tibia.
ABILENE, TEXAS—
Rolling Frito-Lay Sales, LP
An employee was using a handheld grinder to cut a bolt. The grinding wheel broke apart and a fragment struck the employee s right hand, causing a laceration to the palm near the little finger.
COLUMBUS, OHIO—
Blackburn's Fabrication, Inc.
An employee was operating a brake press when the top die broke, causing the bottom die to roll out and onto the employee's legs. Both of the employee's legs were crushed below the knee, and both legs were partially amputated. The employee's left leg was also fractured above the knee.
ORLANDO, FLORIDA—
Textron Aviation Inc. (Orlando Service Center)
A pressurized aircraft nose landing gear strut assembly was being disassembled. The gland nut dislodged under pressure and made contact with an employee's left hand, breaking it.