Ascend Performance Materials, LLC

Flash fire · Thermal burns second degree

Federal OSHA recorded a severe workplace injury at Ascend Performance Materials, LLC, 518 South Bay St, FOLEY, ALABAMA 36535 on , Thermal burns second degree, affecting the head and neck.

Watch Ascend Performance Materials, LLC for free Get an email when a new federal OSHA severe-injury report for Ascend Performance Materials, LLC is published. One employer, no account, unsubscribe in one click.

An employee was troubleshooting a compound extrusion line. As they opened a vent, fumes from the stearic acid additive ignited when exposed to air, causing a flash fire. Molten plastic in the line contacted their lower face and neck, resulting in first- and second-degree burns. A face shield was not used at the time of the incident.

Hospitalized Head and neck Chemicals, hazardous materials n.e.c.

View Ascend Performance Materials, LLC's full OSHA safety record →