2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Kinetics Noise Control

Injury · Other recordable case

On , an injury at Kinetics Noise Control in Dublin, OH 43016 resulted in other recordable case. Employee was assembler in acoustical ceiling tile and panel installation.

Establishment
Kinetics Noise Control
Parent company
Kinetics Noise Control Inc. - Dublin, OH
Street
6300 Irelan PL
City
Dublin
State
OH
ZIP
43016
On-site location
Ovations
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Employee just got back from lunch and went to use router on working surface to help create a proper finish

Employee turned on router while pinky finger was close to router bit. It made contact with the finger.

Doctor gave ICD codes S61.319A (cut on finger) and S62.637B (broken little finger)

The router bit is what caused the damage.

Using a rooter when it made contact with [REDACTED] breaking figure

Job description
Assembler
SOC code
51-2099 — Assemblers and Fabricators, All Other
NAICS code
238310 — Acoustical ceiling tile and panel installation
NAICS vintage
2022
Avg employees
190
Total hours worked
336137
EIN
311288024
Establishment ID
1193419
Employer case #
46197
Date of incident
Shift started
7:00
Time of incident
12:08
Filing year
2024
Submitted
31JAN2025:20:06:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.