2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: FXI, Inc. - Santa Teresa

Injury · Job transfer or restriction

On , an injury at FXI, Inc. - Santa Teresa in Santa Teresa, NM 88008 resulted in job transfer or restriction. Employee was laboratory Technician in polyurethane foam products manufacturing.

Establishment
FXI, Inc. - Santa Teresa
Parent company
FXI, Inc.
Street
2500 Airport Road
City
Santa Teresa
State
NM
ZIP
88008
On-site location
Quality Lab
Outcome
Job transfer or restriction (code 3)
Type
Injury (code 1)
Days restricted or transferred
24

The employee was cutting a piece of acrylic and cut off part of the tip of the left 1st. digit

The laboratory EE noticed that the acrylic did not have the correct irregular area and decided to cut the excess acrylic material with a retractable knife. At the time of making the cut EE didn 't have safety gloves; with the force applied with the right hand on the acrylic the movement of hand with the knife continued towards the left thumb causing a laceration.

Laceration in left thumb with damage to nail

A retractable knife when cutting acrylic.

Left Thumb laceration when the EE was try to cut an acrylic template with a metal knife in quality lab.

Job description
Laboratory Technician
SOC code
19-4031 — Chemical Technicians
NAICS code
326150 — Polyurethane foam products manufacturing
NAICS vintage
2012
Avg employees
145
Total hours worked
320999
EIN
270283137
Establishment ID
707114
Employer case #
2
Date of incident
Shift started
6:00
Time of incident
10:15
Filing year
2024
Submitted
24FEB2025:21:09:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.