Eugene, OR —
OSHA Injury Report: Precision Machine & Manufacturing
Other illness · Other recordable case
At a glance
On , an other illness at Precision Machine & Manufacturing in Eugene, OR 97402 resulted in other recordable case. Employee was machinist in airlocks, fabricated metal plate work, manufacturing.
Where did this happen?
- Establishment
- Precision Machine & Manufacturing
- Parent company
- Precision Machine & Manufacturing
- Street
- 1290 S. Bertelsen Rd
- City
- Eugene
- State
- OR
- ZIP
- 97402
- On-site location
- Nomura
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Other illness (code 6)
Before the incident
The employee was using the machine to drill a hole in a pipe.
What happened
The drill bit that was being used hit a hard spot in the pipe and broke. This caused a piece of the drill bit to fly and hit the employee in the face.
Injury or illness
Puncture to his nose
Object or substance involved
A broken piece of the drill bit.
Summary line
Puncture to nose
Employee and industry
- Job description
- Machinist
- SOC code
- 51-4041 — Machinists
- NAICS code
- 332313 — Airlocks, fabricated metal plate work, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 40
- Total hours worked
- 83220
- EIN
- 930749557
- Establishment ID
- 1236547
- Employer case #
- 8877874
When (timing detail)
- Date of incident
- Shift started
- 5:00
- Time of incident
- 7:15
- Filing year
- 2025
- Submitted
- 27JAN26:23:24:00
Source