Suwanee, GA —
OSHA Injury Report: Geiger Automotive USA, Inc
Injury · Other recordable case
At a glance
On , an injury at Geiger Automotive USA, Inc in Suwanee, GA 30024 resulted in other recordable case. Employee was automation Engineer in motor vehicle moldings and extrusions, plastics, manufacturing.
Where did this happen?
- Establishment
- Geiger Automotive USA, Inc
- Parent company
- Geiger Automotive
- Street
- 375 Satellite Blvd NE
- City
- Suwanee
- State
- GA
- ZIP
- 30024
- On-site location
- Injection molding machine #15
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Employee was connecting an air hose to a pressurized air line via a quick connect type fitting. One part of the fitting is on the fixed air line and the part on the hose.
What happened
The employee thought the fitting had been made and released his grip on the hose part of the fitting. The connection however was not completed and the pressure in the line blew the hose fitting upward striking him in the face.
Injury or illness
Cut on face.
Object or substance involved
The fitting on the end of the air hose that was blown into his face.
Summary line
Cut on face
Employee and industry
- Job description
- Automation Engineer
- SOC code
- 17-2141 — Mechanical Engineers
- NAICS code
- 326199 — Motor vehicle moldings and extrusions, plastics, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 156
- Total hours worked
- 309150
- EIN
- 273438571
- Establishment ID
- 873104
- Employer case #
- 3
When (timing detail)
- Date of incident
- Shift started
- 15:35:00.000
- Time of incident
- 16:45:00.000
- Submitted
- 07FEB24:19:13:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.