2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Chromalloy San Diego

Injury · Days away from work

On , an injury at Chromalloy San Diego in San Diego, CA 92121 resulted in days away from work. Employee was engine Mechanic I in turbine Engine Parts Repair and Service.

Establishment
Chromalloy San Diego
Parent company
Chromalloy Corporation
Street
7007 Consolidated Way
City
San Diego
State
CA
ZIP
92121
On-site location
Rotors
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
1
Days restricted or transferred
5

Manual hoist chain to remove disk from the oven

While using the manual hoist chain to remove the stage 1 disk from the oven the synchronized out-of-service hoist chain got entangled behind the oven door was dragged over it and struck the employee on the back of the head. Employee was driven to Concentra who referred him to a list of hospitals for a CT scan. Employee was driven to the hospital where the CT scan was completed. There were no findings from the CT scan and the Doctor told the employee to take 1 day off from work. Employee returned to Concentra for a follow up the next day and they were diagnosed with a concussion. Employee returned to work with restrictions. [REDACTED] returned to full duty.

Contusion

Hoist hook

Contusion to Head caused by Hoist hook

Job description
Engine Mechanic I
SOC code
49-3011 — Aircraft Mechanics and Service Technicians
NAICS code
488190 — Turbine Engine Parts Repair and Service
NAICS vintage
2012
Avg employees
221
Total hours worked
552192
EIN
742462992
Establishment ID
727110
Employer case #
IN-202502
Date of incident
Shift started
5:30
Time of incident
10:30
Filing year
2025
Submitted
09FEB26:14:25:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.