Houston, TX —
OSHA Injury Report: PV Fluid Products
Injury · Job transfer or restriction
At a glance
On , an injury at PV Fluid Products in Houston, TX 77066 resulted in job transfer or restriction. Employee was cell Coordinator in oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing.
Where did this happen?
- Establishment
- PV Fluid Products
- Parent company
- PV Fluid Products
- Street
- 11901 Cutten Rd.
- City
- Houston
- State
- TX
- ZIP
- 77066
- On-site location
- Disassembly
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 10
Before the incident
Operator was removing a face seal from a tube using a blade.
What happened
While cutting away rubber with a blade the blade cut violently through the rubber and the operator struck his own wrist with the blade causing a deep laceration.
Injury or illness
Laceration to wrist.
Object or substance involved
Box Cutting Razor Blade
Summary line
Laceration to the wrist and needed stitches.
Employee and industry
- Job description
- Cell Coordinator
- SOC code
- 43-9199 — Office and Administrative Support Workers, All Other
- NAICS code
- 333132 — Oil and gas field-type drilling machinery and equipment (except offshore floating platforms) manufacturing
- NAICS vintage
- 2022
- Avg employees
- 167
- Total hours worked
- 388768
- Establishment ID
- 1114663
- Employer case #
- 1
When (timing detail)
- Date of incident
- Shift started
- 6:00:00.000
- Time of incident
- 12:30:00.000
- Submitted
- 08FEB24:19:25:00
Source