2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Genpak Longview

Injury · Days away from work

On , an injury at Genpak Longview in Longview, TX 75604 resulted in days away from work. Employee was maintenance in polystyrene foam packaging manufacturing.

Establishment
Genpak Longview
Parent company
Genpak LLC
Street
1101 West Harrison Road
City
Longview
State
TX
ZIP
75604
On-site location
Silo 8 Roof Blower
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
5
Days restricted or transferred
14

Mechanic had replaced the belt on the roof blower for [REDACTED].

Mechanic was testing the pump and turning the belt by hand to listen for unusual noise. As he was pulling pushing the belt the tip of his finger got caught between the belt and pulley.

Tip of mechanic 's left index finger was severed.

Belt and pulley for LV8 blower

Mechanic stated that he got his finger caught between a pelt and pulley on blowers

Job description
Maintenance
SOC code
49-9041 — Industrial Machinery Mechanics
NAICS code
326140 — Polystyrene foam packaging manufacturing
NAICS vintage
2022
Avg employees
210
Total hours worked
443531
EIN
418036221
Establishment ID
1255516
Employer case #
LV-03
Date of incident
Shift started
7:00
Time of incident
9:50
Filing year
2025
Submitted
16FEB26:21:19:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.