2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Continuing Care Center

Injury · Other recordable case

On , an injury at Continuing Care Center in Canandaigua, NY 14424 resulted in other recordable case. Employee was eD Rep Tech in nursing homes.

Establishment
Continuing Care Center
Parent company
UR Medicine Thompson Health
Street
350 Parrish St
City
Canandaigua
State
NY
ZIP
14424
On-site location
Hospital-01-Lab
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Lab Draw

Associate alleges On my first attempt at drawing blood [REDACTED] during training I was using a 22G with a vacutainer and drawing on the pt 's left antecubital (AC). I inserted the needle into the pt 's AC incorrectly but instinctively holding it as I would hold the IVs I 've previously used in EMS [REDACTED] ago because of muscle memory. I attempted to fix my hand position while filling the first SST and I saw the vein blow. I withdrew the needle from the pt 's AC while covering the location with a folded 2x2. As I went to close the cap on the needle I closed it incorrectly because of my muscle memory from the IVs I 've previously used and my finger slid off the side of the cap and the anterior aspect of the tip of my right first pointer finger (closest to thumb) grazed against the needle enough to where I felt it. I didn 't feel pain specifically and I wasn 't sure if it broke skin. Not wanting to upset the pt I waited until [REDACTED] (my proctor) completed the lab work on the pt 's

Sharps exposure Right Pointer finger

BD Vacutainer Eclipse needle 22 G 1 1 4

Sharps exposure right pointer finger; BD Vacutainer Eclipse needle 22 G 1 1 4

Job description
ED Rep Tech
SOC code
29-2099 — Health Technologists and Technicians, All Other
NAICS code
623110 — Nursing homes
NAICS vintage
2012
Avg employees
344
Total hours worked
338062
EIN
160743024
Establishment ID
849863
Employer case #
5099
Date of incident
Shift started
6:45
Time of incident
7:55
Filing year
2025
Submitted
25FEB26:16:59:00