Sterling Heights, MI —
OSHA Injury Report: VAN DYKE PLNT
Hearing loss · Other recordable case
At a glance
On , a hearing loss at VAN DYKE PLNT in Sterling Heights, MI 48314 resulted in other recordable case. Employee was rEFRIGERATION MAINTENANCE AND INST in manufacture of Automotive Transmissions.
Where did this happen?
- Establishment
- VAN DYKE PLNT
- Parent company
- Ford Motor Company
- Street
- 41111 Van Dyke
- City
- Sterling Heights
- State
- MI
- ZIP
- 48314
- On-site location
- 741021
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Hearing loss (code 5)
Before the incident
On [REDACTED] the employee was seen at VEPC medical for annual audio testing. Testing showed a possible STS decline in the right ear. Retest scheduled for [REDACTED]
What happened
Possible STS decline Rt ear
Injury or illness
Noise-induced hearing loss Ear(s) Right
Object or substance involved
? noise exposure
Summary line
Noise-induced hearing loss Ear(s) Right
Employee and industry
- Job description
- REFRIGERATION MAINTENANCE AND INST
- SOC code
- 49-9021 — Heating, Air Conditioning, and Refrigeration Mechanics and Inst
- NAICS code
- 336350 — Manufacture of Automotive Transmissions
- NAICS vintage
- 2012
- Avg employees
- 1356
- Total hours worked
- 2519866
- EIN
- 380549190
- Establishment ID
- 352360
- Employer case #
- 5026-25-0
When (timing detail)
- Date of incident
- Shift started
- 6:04
- Filing year
- 2025
- Submitted
- 26FEB26:11:35:00
Source