OSHA Injury Report: Hailiang Copper Texas Inc

Injury · Days away from work

On , an injury at Hailiang Copper Texas Inc in 5000 I10 Building #16, Sealy, TX 77474 resulted in days away from work. Employee was technician in bronze products, rolling, drawing, or extruding, made from purchased copper or in integrated secondary smelting and rolling, drawing or extruding plants.

Watch Hailiang Copper Texas Inc for free Get an email when a new federal OSHA severe-injury report for Hailiang Copper Texas Inc is published. One employer, no account, unsubscribe in one click.
Parent company
Hailiang Copper Texas Inc.
Street
5000 I10 Building #16
City
Sealy
State
TX
ZIP
77474
On-site location
Jumbo Coil Machine #4
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
3
Days restricted or transferred
30

The technician was starting a copper coil on the jumbo coil rewinding machine #4 after changing a roller.

The technician was using their hands to flatten the copper coil on the rewinding table when their hand got caught up between the table pin and the 1st copper tube roller.

Compound fracture to the left index finger

Metal table pin and steel roller.

Compound Fracture to left index finger from pinch point.

Job description
Technician
SOC code
17-3023: Electrical and Electronic Engineering Technologists and Technic
NAICS code
331420: Bronze products, rolling, drawing, or extruding, made from purchased copper or in integrated secondary smelting and rolling, drawing or extruding plants
NAICS vintage
2022
Employees at this establishment (2025 average)
153
Hours worked at this establishment (2025 total)
414,906
EIN
832271146
Establishment ID
1260509
Employer case #
4
Date of incident
Shift started
08:00
Time of incident
16:05
Filing year
2025
Submitted to OSHA
2026-02-26

View Hailiang Copper Texas Inc's full OSHA safety record →