2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Precision Strip, Inc. Minster

Injury · Other recordable case

On , an injury at Precision Strip, Inc. Minster in Minster, OH 45865 resulted in other recordable case. Employee was assistant Operator.

Establishment
Precision Strip, Inc. Minster
Parent company
Precision Strip, Inc.
Street
86 S Ohio
City
Minster
State
OH
ZIP
45865
On-site location
Other
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Operator did not have his edge guide set correct when threading up a coil and when it went into the head he did not have...

[REDACTED] was threading material into the slitter line when the operator side edge guide was not set correctly. This left no side trim requiring him to back material into the shear. When the scrap was cut the wide trim became stuck in the chute. [REDACTED] opened the gate and tried to pull it by hand. The scrap fell and pinched his left index finger against the platform resulting in a cut that required five stitches. He used his hands instead of a no touch tool. Maintenance welded a plate on the drive side to prevent scrap from catching again. The root cause was scrap getting stuck and being pulled by hand. Corrective actions include sharing the incident welding plates to stop sticking reinforcing the use of no touch tools retraining on proper threading and checking other Minster slitters for similar conditions.

Laceration req Medical Treatment index finger

entry shear ramp

Description of Incident [REDACTED] was attempting to clear scrap from the entry shear scrap chute. The scrap was caught on the drive side of the line. When freeing the sample it pinched his finger between the platform and chute. This blew the side of his

Job description
Assistant Operator
SOC code
00-9900 — Insufficient Information - NIOSH
NAICS code
423510
NAICS vintage
2012
Avg employees
251
Total hours worked
445601
EIN
341207681
Establishment ID
86560
Employer case #
4
Date of incident
Filing year
2025
Submitted
27FEB26:14:04:00