Clayton, NC —
OSHA Injury Report: Structured Steel Products Corporation
Injury · Days away from work
At a glance
On , an injury at Structured Steel Products Corporation in Clayton, NC 27520 resulted in days away from work. Employee was welder team leader in structural steel, fabricated, manufacturing.
Where did this happen?
- Establishment
- Structured Steel Products Corporation
- Parent company
- The Hales Group
- Street
- 8027 US 70 BUS W
- City
- Clayton
- State
- NC
- ZIP
- 27520
- On-site location
- girder shop
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 46
Before the incident
repositioning a closer apparatus over a girder with an overhead crane
What happened
as the closer apparatus was being lifted off of the girder the leg of the closer slipped off of a rail it was on causing the closer to drop at the same time the employee had is hand on the top of the girder flange causing it to pinch his right index fingertip between the closing apparatus and flange of the girder
Injury or illness
partial amputation of right index fingertip
Object or substance involved
fingertip being in a crush zone between the girder flange and closing apparatus.
Summary line
right index finger caught in crush zone between girder flange and closer apparatus causing partial amputation of right index fingertip which was reported to NCDOL within 24hr of diagnosis received from hand surgeon 's notes.
Employee and industry
- Job description
- welder team leader
- SOC code
- 51-4121 — Welders, Cutters, Solderers, and Brazers
- NAICS code
- 332312 — Structural steel, fabricated, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 70
- Total hours worked
- 128784
- EIN
- 561316081
- Establishment ID
- 957133
- Employer case #
- 23-06
When (timing detail)
- Date of incident
- Shift started
- 6:30:00.000
- Time of incident
- 8:40:00.000
- Submitted
- 15JAN24:16:18:00
Source