Millersburg, PA —
OSHA Injury Report: Thermo Fisher Scientific Millersburg Main Campus
Injury · Other recordable case
At a glance
On , an injury at Thermo Fisher Scientific Millersburg Main Campus in Millersburg, PA 17061 resulted in other recordable case. Employee was operator II in bags, plastics film, single wall or multiwall, manufacturing.
Where did this happen?
- Establishment
- Thermo Fisher Scientific Millersburg Main Campus
- Parent company
- Thermo Fisher Scientific
- Street
- 163 Research Lane
- City
- Millersburg
- State
- PA
- ZIP
- 17061
- On-site location
- Molding Cleanroom
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Employee was operating Tippman Press.
What happened
The [REDACTED] utilizes a two-handed control. The employee was using her palms to operate the press. The employee had her fingers pointing down which put her hands closer to the point of operation. The employee pressed both controls with her palms and the bottom press plate came up. When the plate came up the employee did not realize the placement of her fingers and 8 of her fingers got caught in the press.
Injury or illness
Two of her fingers had hairline fractures.
Object or substance involved
Employee got her fingers caught between the two press plates of the Tippman Press.
Summary line
Crushed 8 of the employee 's fingers.
Employee and industry
- Job description
- Operator II
- SOC code
- 51-4199 — Metal Workers and Plastic Workers, All Other
- NAICS code
- 326111 — Bags, plastics film, single wall or multiwall, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 651
- Total hours worked
- 732611
- EIN
- 232444074
- Establishment ID
- 85067
- Employer case #
- 907
When (timing detail)
- Date of incident
- Shift started
- 5:00:00.000
- Time of incident
- 13:00:00.000
- Submitted
- 29JAN24:13:45:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.