2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Corning Life Sciences CLS Vineland,New Jersey

Injury · Other recordable case

On , an injury at Corning Life Sciences CLS Vineland,New Jersey in Vineland, NJ 8360 resulted in other recordable case. Employee was maintenance in other Pressed and Blown Glass and Glassware Manufacturing.

Establishment
Corning Life Sciences CLS Vineland,New Jersey
Parent company
Corning Pharmaceutical Glass LLC
Street
563 Crystal Ave
City
Vineland
State
NJ
ZIP
8360
On-site location
Batch Mixer Platform
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

EE was using a cordless drill to drill out broken hardware on batch mixing equipment EE changed battery on the drill and switched from a crouching position to a standing one When EE returned to drilling drill bit caught and ripped drill from EEs control Drill spun around and struck EE on lowerleft portion of chin causing a laceration

EE was using a cordless drill to drill out broken hardware on batch mixing equipment EE changed battery on the drill and switched from a crouching position to a standing one When EE returned to drilling drill bit caught and ripped drill from EEs control Drill spun around and struck EE on lowerleft portion of chin causing a laceration

Laceration Cut Open Wound Head - Facial Area Chin

Cordless Drill

Laceration Cut Open Wound Head Facial Area Chin Cordless Drill Struck by

Job description
Maintenance
SOC code
49-9041 — Industrial Machinery Mechanics
NAICS code
327212 — Other Pressed and Blown Glass and Glassware Manufacturing
NAICS vintage
2022
Avg employees
314
Total hours worked
556040
EIN
475080607
Establishment ID
1261984
Employer case #
706
Date of incident
Shift started
7:00
Time of incident
10:45
Filing year
2024
Submitted
21JAN2025:16:51:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.