FARGO, ND —
OSHA Inspection: BERNIE'S WINES & LIQUORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BERNIE'S WINES & LIQUORS in 1557 UNIVERSITY DRIVE SOUTH, FARGO, ND 58103 (NAICS 000000). OSHA activity number 102763000.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BERNIE'S WINES & LIQUORS
- Site address
- 1557 UNIVERSITY DRIVE SOUTH
- City
- FARGO
- State
- ND
- ZIP
- 58103
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5921
- Employees
- 12
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- May 15, 2002
- Penalty
- Initial $450 · Current $338 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator where the elevator operating capacity was not identified exposing employees to a potential for injury. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 207.3a: Every elevator shall be provided with a capacity plate and a data plate permanently and securely fastened in place. The capacity plate shall be conspicuously positioned inside the car. For freight elevators the load rating shall be based on not less than 50 lb/square ft. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $337.50
- — Z (S) $450.00
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- May 15, 2002
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator where the elevator was not identified as one for freight only exposing employees to a potential for injury. Among other methods, one feasible and acceptable method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 207.5: Signs Required in Freight Elevator Cars: Rule 207.5a (2): For elevators not permitted to carry passengers, the sign shall read: "THIS IS NOT A PASSENGER ELEVATOR, NO PERSONS OTHER THAN THE OPERATOR AND FREIGHT HANDLERS ARE PERMITTED TO RIDE ON THE ELEVATOR". Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
- Penalty
- Initial $750 · Current $563 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to a potential for injury created by the lack of an emergency stop switch on the car and other control panels on the main floor and basement level. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 210.2 (e): Emergency Stop Switch: An emergency stop switch shall be provided in the car and located in or adjacent to each car operating panel. When opened, this switch shall cause the electric power to be removed from the elevator driving machine motor and brake. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $562.50
- — Z (S) $750.00
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to a potential for injury where the elevator operating controls on the car and at each landing were of the type for use with a garage door and marked open/close rather than up/down for elevator use. Among other methods, one feasible and acceptable method to correct this hazard is to install operating controls on the elevator car and at each landing that are designed for use with freight elevators. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
- Penalty
- Initial $750 · Current $563 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to the potential hazard of becoming caught between the freight elevator car and elevator shaft walls. Among other methods, one feasible and acceptable method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 204.1a: Enclosure Required. Elevators shall be equipped with a car enclosure. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $562.50
- — Z (S) $750.00
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- May 15, 2002
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to potential overhead hazards in the elevator shaft. Among other methods, one feasible and acceptable method to correct this hazards is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 204.1f: Car Enclosure Tops. Tops of car enclosures shall be so designed and installed as to be capable of sustaining a load of 300 lb (136 kg) on any area 2 ft (610 mm) by 2 ft (610 mm) and 100 lb (45 kg) applied at any point. Simultaneous application of these loads is not required. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to a potential for injury created by unapproved lighting. Among other methods, one feasible and acceptable method to abate this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 204.7a: Illumination and Outlets Required. Cars shall be provided with an electric light or lights conforming to the following: 1. Not less than two lamps shall be provided. 2. The minimum illumination at the car threshold, with the door closed, shall not be less than: For freight elevators 2 1/2 foot candles (27 lux). Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
- Penalty
- Initial $750 · Current $563 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to the potential for injury created by the lack of doors or gates on the elevator car. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 204.4a: Where Required. A door or gate shall be provided at each entrance to the car. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $562.50
- — Z (S) $750.00
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- Jul 15, 2002
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) For employees operating the freight elevator and exposed to a potential crushing injury created by the lack of a guard at the basement level elevator landing. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 110.1: Entrances and Emergency Doors Required. All elevators, hoistway-landing openings shall be provided with an entrance which shall guard the full height and width of the openings. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Apr 12, 2002
- Abate by
- May 15, 2002
- Penalty
- Initial $450 · Current $338 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) The employer failed to maintain inspection, testing, and maintenance records for the freight elevator exposing employees who operate the freight elevator to potential injury. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the requirements set forth in ANSI/ASME A17.1-1984 Rule 1004: Routine Inspection and Tests of Passenger and Freight Hydraulic Elevators. Rule 1006: Acceptance Inspection and Tests of Passenger and Freight Hydraulic Elevators. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $337.50
- — Z (S) $450.00
More inspections at Bernie'S Wines & Liquors
View Bernie'S Wines & Liquors's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102763000.