POTTSTOWN, PA —
OSHA Inspection: SUPERIOR METAL PRODUCTS CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUPERIOR METAL PRODUCTS CO., INC. in 116 BERKS STREET, POTTSTOWN, PA 19464 (NAICS 000000). OSHA activity number 102873213.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPERIOR METAL PRODUCTS CO., INC.
- Site address
- 116 BERKS STREET
- City
- POTTSTOWN
- State
- PA
- ZIP
- 19464
- Mailing
- P.O. BOX 595, POTTSTOWN, PA 19464
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3443
- Employees
- 70
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 29, 1990
- Abate by
- Mar 1, 1990
- Penalty
- Initial $560 · Current $160 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards of underhung crane failure: a) Harrington Overhead Underhung Crane - Shear Area of plant had numerous safety deficencies such as: 1) Hoist panel needs to have a flat cable connector plug installed. 2) The weld on the lower block nut is broken and needs to be rewelded. 3) The upper sheave shaft is too short for the application and needs to be replaced with the proper length shaft. 4) The cast end trolley stop pad is missing and needs to be replaced. 5) The off button on the pendant station does not function and needs to be either repaired or replaced. 6) The drive wheels opposite the main collector need to have the bearings replaced. 7) The drive wheels on the main collector side are digging into the rail. This may be caused by improper crane span. 8) A door track hanger is missing on the festoon system and needs to be replaced. 9) The door track hits an angle support for a shelf at the north end of the building. This angle support should be relocated if possible. 10) There is excessive wiring hanging from the main collectors. 11) The crane capacity sign is incorrectly marked on one side. Among other methods, feasible and acceptable abatement methods to correct this hazard is to: 1) Correct all safety deficiencies. 2) Conduct frequent and regular inspections of the crane as referenced in ANSI (American National Standard Institute) requirement B30.11.2.1-1979 Monorail Systems and Underhung Cranes.
Recent events (2)
- — I (S) $160.00
- — Z (S) $560.00
1910.212 A03 II
- Issued
- Jan 29, 1990
- Abate by
- Mar 1, 1990
- Penalty
- Initial $480 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $480.00
1910.217 C03 IIA
- Issued
- Jan 29, 1990
- Abate by
- Apr 1, 1990
- Penalty
- Initial $480 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $480.00
1910.217 C03 VIII
- Issued
- Jan 29, 1990
- Abate by
- Apr 1, 1990
- Penalty
- Initial $480 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $480.00
1910.252 A02 IVC
- Issued
- Jan 29, 1990
- Abate by
- Feb 1, 1990
- Penalty
- Initial $320 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $320.00
1910.22 D02
- Issued
- Jan 29, 1990
- Abate by
- Feb 5, 1990
1910.106 E09 III
- Issued
- Jan 29, 1990
- Abate by
- Feb 1, 1990
1910.217 C02 I
- Issued
- Jan 29, 1990
- Abate by
- Feb 1, 1990
More inspections at Superior Metal Products CO., INC.
View Superior Metal Products CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source