PHILADELPHIA, PA ·
OSHA Inspection: COIL PLUS PA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COIL PLUS PA in MILNOR & BLEIGH STREETS, PHILADELPHIA, PA 19136 (NAICS 000000). OSHA activity number 102938552.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COIL PLUS PA
- Site address
- MILNOR & BLEIGH STREETS
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19136
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5051
- Employees
- 31
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 C03
- Issued
- Jul 19, 1995
- Abate by
- Jul 24, 1995
- Penalty
- Initial $562 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $562.00
1910.179 N03 VI
- Issued
- Jul 19, 1995
- Abate by
- Jul 24, 1995
- Penalty
- Initial $562 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $562.00
1910.179 N03 XI
- Issued
- Jul 19, 1995
- Abate by
- Jul 24, 1995
Recent events (2)
- · I (S)
- · Z (S)
1910.212 A01
- Issued
- Jul 19, 1995
- Abate by
- Jul 24, 1995
- Penalty
- Initial $562 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $562.00
1910.212 A03 II
- Issued
- Jul 19, 1995
- Abate by
- Aug 21, 1995
- Penalty
- Initial $1,125 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $1125.00
1910.303 G01 I
- Issued
- Jul 19, 1995
- Abate by
- Jul 24, 1995
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Coil Plus PA
View Coil Plus PA's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 102938552.