BIDDEFORD, ME ·
OSHA Inspection: FIBER MATERIALS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FIBER MATERIALS, INC. in BIDDEFORD INDUSTRIAL PARK, BIDDEFORD, ME 04005 (NAICS 000000). OSHA activity number 103393997.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIBER MATERIALS, INC.
- Site address
- BIDDEFORD INDUSTRIAL PARK
- City
- BIDDEFORD
- State
- ME
- ZIP
- 04005
- Mailing
- 5 MORIN STREET, BIDDEFORD, ME 04005
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2899
- Employees
- 500
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 10, 1989
- Abate by
- Oct 10, 1989
- Penalty
- Initial $800 · Current $800
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns from the operation of graphitizers. Among other methods, one feasible and acceptable abatement method is to provide additional engineering safeguards: Building 1, Area 6 - The following engineering safeguards were not provided to minimize employee exposure to burns: a) Firewalls were not provided between the three graphs (#22, #23 and #26). b) Automatic closing fire doors in said fire walls were not provided. c) Automatic temperature monitoring was not provided. d) Closed circuit TV was not installed to provided remote viewing graphs. e) Increased insulation was not provided inside the graphs. f) Combustible gas sensing with automatic alarm was not provided. g) Thermal survey of graphs was not provided. h) Emergency cooling of graph extensions complete with emergency water dump capabiltiy was not provided. i) Improved pressure relief (i.e. blowout panels, screws) was not provided in building walls. j) Testing for coil lining integrity was not conducted. k) Hydraulic testing of coils and connections was not performed. l) A preventive Maintenance Program on control panels including ground-fault protection devices and coils was not provided. m) A system was developed to determine a life cycle for the graphs and their critical components.
Recent events (2)
- · P (S) $800.00
- · Z (S) $800.00
More inspections at Fiber Materials, INC.
View Fiber Materials, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103393997.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.