ST. GEORGE, AK ·
OSHA Inspection: SNOPAC PRODUCTS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SNOPAC PRODUCTS INC in M/V SNOPAC-ST. GEORGE, ST. GEORGE, AK 99591 (NAICS 000000). OSHA activity number 107108557.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SNOPAC PRODUCTS INC
- Site address
- M/V SNOPAC-ST. GEORGE
- City
- ST. GEORGE
- State
- AK
- ZIP
- 99591
- Mailing
- 5053 E. MARGINAL WAY SOUTH, SEATTLE, WA 98134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 130
- Ownership type
- Private (A)
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jul 20, 1992
- Penalty
- Initial $2,000 · Current $500 Reduced
General-duty citation text
The alleged violations below have been grouped because they involve similar or related hazards that may increase the potential for injury resulting from an accident. Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees had occasion to utilize restroom facilities that did not have ground fault circuit inter- rupters (GFCI) installed on outlets near sinks. This condi- tion exposed employees to electrical shock in the event they became the path to ground from the outlet and water in the sink or to an appliance dropped in the sink with water. Among other methods, one feasible and acceptable method of abatement would be to install GFCI outlet protection.
Recent events (2)
- · F (S) $500.00
- · Z (S) $2000.00
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jul 20, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees entering and/or working in unlocked utility room #13 had occasion to be near flexible cord run through plywood ceiling to a pigtailed light socket with 40 watt light bulb. This condition exposed employees to possible abraded cord and/or fire hazard and possible shock and burns. Among other methods, one feasible and acceptable abatement method is to install in conduit. (b) M/V Snopac: Employees in the tallying and strapping area had occasion to work near an extension cord that was run from the J-box to the weighing machine over steel girders and support braces. This condition exposed employees to the possible contact with abraded conductors on the extension cord and possible shock, burns and/or electrocution. Among other methods, one feasible and acceptable abatement method is to install the flexible wiring in conduit and provide suitable electric outlet for the weighing machine.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jun 24, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees on the weather deck on the aft starboard side had occasion to walk/work near a quartz halogen light that had the cover missing from the J-box and the bulb missing. This condition exposed employees to possible contact with exposed conductors resulting in shock, burns and electrocution. Among other methods, one acceptable and feasible method of abatement would be to install the cover and install a bulb.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jun 20, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees using a portable quartz halogen light in the strapping and tallying area had occasion to be exposed to conductors (electrical) that did not have p roper strain relief or splice to prevent conductors from being pulled out of light. This condition exposed employees to possible shock, burns, and electrocution. Among other methods, one feasible method of abatement would be to install proper strain relief device.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jul 20, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock and burns: (a) M/V Snopac: Employees entering and/or working in unlocked utility room #13 had occasion to be exposed to unguarded electric light bulb that is pigtailed into a flexible cord. This condition exposed employees to a possible broken bulb and exposure to live bare conductors and shock or electrical burns. Among other methods, one feasible and acceptable method of abatement would be to install proper guard over bulb after installed in properly installed fixture.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jun 19, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees entering and/or working in unlocked utility room #13 had occasion to be exposed to unguarded live conductors on a 208 volt hot water heat with terminal (elec- tric) cover missing. This condition exposed employees to possible contact with live electric conductors and shock or electrical burns. Among other methods, one acceptable and feasible method of abatement would be to replace the manufactured cover designed for enclosure.
Recent events (2)
- · F (S)
- · Z (S)
5(a)(1)
- Issued
- Jun 16, 1992
- Abate by
- Jun 19, 1992
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a recognized hazard of electrical shock or burns: (a) M/V Snopac: Employees entering and/or working in unlocked utility room #13 had occasion to be exposed to unguarded live conductors in a 220 volt, three-phase access panel with missing cover. This condition exposed employees to possible contact with the live conductors and shock or electrical burns. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the missing cover over the opening.
Recent events (2)
- · F (S)
- · Z (S)
1910.22 C
- Issued
- Jun 16, 1992
- Abate by
- Jul 6, 1992
- Penalty
- Initial $1,200 · Current $600 Reduced
Recent events (2)
- · F (S) $600.00
- · Z (S) $1200.00
1910.134 F02 I
- Issued
- Jun 16, 1992
- Abate by
- Jun 19, 1992
- Penalty
- Initial $1,600 · Current $1,600
Recent events (2)
- · F (S) $1600.00
- · Z (S) $1600.00
1910.134 F05 I
- Issued
- Jun 16, 1992
- Abate by
- Jun 19, 1992
- Penalty
- Current $200
Recent events (2)
- · F (S) $200.00
- · Z (S)
1910.151 C
- Issued
- Jun 16, 1992
- Abate by
- Jul 20, 1992
- Penalty
- Initial $1,600 · Current $800 Reduced
Recent events (2)
- · F (S) $800.00
- · Z (S) $1600.00
1904.2 A
- Issued
- Jun 16, 1992
- Abate by
- Jun 19, 1992
- Penalty
- Initial $800 · Current $400 Reduced
Recent events (2)
- · F (O) $400.00
- · Z (O) $800.00
More inspections at Snopac Products INC
View Snopac Products INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 107108557.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.