OSHA Inspection: NEWARK REFRIGERATED WAREHOUSE, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of NEWARK REFRIGERATED WAREHOUSE, INC. in AVENUE C AND VANDERPOOL STREET, NEWARK, NJ 07114 (NAICS 000000). OSHA activity number 107654212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Newark Refrigerated Warehouse, INC. — free Get an email when a new federal OSHA severe-injury report for Newark Refrigerated Warehouse, INC. is published. One employer, no account, unsubscribe in one click.
Site address
AVENUE C AND VANDERPOOL STREET
City
NEWARK
State
NJ
ZIP
07114
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
4222
Employees
25
Ownership type
A

88 citations on file for this inspection.

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 28, 1990
Abate by
Dec 1, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 6, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Serious Gravity 10 3 instances 10 exposed
Issued
Nov 27, 1990
Abate by
Dec 11, 1990
Penalty
Initial $900 · Current $400 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
Employees were exposed to the hazard of being caught and/or crushed
between the elevator and shaftway wall or sills. Dowels were missing
on car gates for elevator(s):
a) #1, Side B, (5) five dowels middle panel;
b) #3, Side A, No dowels on lower panel;
c) #3, Side B, (4) four dowels lower panel.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Immediately replace or repair broken gate panels.
Referance Publication(s):
a) American National Standard Institute/American Society of Mechanical
Engineers - A 17.3 - 1986 - Section 2.6.1(b).
b) American National Standard Institute/American Society of Mechanical
Engineers - A 17.1 - 1981 - Section 204.4(b)(2).
Recent events (2)
  • — J (S) $400.00
  • — Z (S) $900.00

5(a)(1)

Serious Gravity 01 4 instances 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
Employee(s) were exposed to the hazard of being crushed by the load
or the industrial truck in the elevator. An emergency lighting system
was not provided in elevators #1, 2, 3 and 4 that would be
automatically turned on in all elevators in service immediately
after normal car lighting power failed.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Provide an emergency lighting system for all elevators in service.
Emergency lights shall be automatically turned on immediately
after normal car lighting power fails.
Reference Publication(s):
a) American National Standards Institute/American Society of Mechanical
Engineers - A 17.3 - 1986 - Section 1.5(b).
b) American National Standard Institute/American Society of Mechanical
Engineers - A 17.1 - 1981 - Section 204.7(a)(3)(a).
Recent events (2)
  • — J (S)
  • — Z (S)

5(a)(1)

Serious Gravity 01 4 instances 10 exposed
Issued
Nov 27, 1990
Abate by
Jan 9, 1991
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnsih employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
Employee(s) were exposed to the hazard of being trapped in elevators
#1, 2, 3 and 4 without a means of an emergency alarm system during an
emergency such as fire, injury, mechanical failure, etc. An emergency
signal to alert personnel of an emergency and a means for a two-way
conversation between each elevator at a readily accessible point
outside the hoistway was not provided.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Install an audible signaling device, operable from the emergency stop
switch and from a switch marked "ALARM" which are located in or
adjacent to each car operating panel. The signaling device shall be
located inside the building and audible inside the car and outside
the hoistway. One signaling device may be used for a group of
elevators.
2) Install a means of two-way conversation between each elevator and a
readily accessible point outside the hoistway (telephone, intercom,
etc.) when employees are left unattended.
Reference Publication(s):
a) American National Standard Institute/American Society of Mechanical
Engineers - A 17.3 - 1986 - Section 3.11.1(a), 3.11.1(b).
b) American National Standard Institute/American Society of Mechanical
Engineers - A 17.1 - 1981 - Section 2.11.1(b).
Recent events (2)
  • — J (S)
  • — Z (S)

5(a)(1)

Serious Gravity 01 4 instances 3 exposed
Issued
Nov 27, 1990
Abate by
Dec 27, 1990
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
Employee(s) were exposed to the hazard of a fall of approximately (4)
feet into an elevator pit. Proper fixed ladders were not provided
where the pit exceeded (3) three feet below the sill of the hoistway
openings on elevators #1, 2, 3 and 4.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Install in all (4) four elevator pits a fixed vertical ladder of
non-combustible material.
Reference Publication(s):
a) American National Standard Institute/American Society of Mechanical
Engineers - A 17.3 - 1986 - Section 2.3.1.
b) American National Standard Institute/American Society of Mechanical
Engineers - A 17.1 - 1981 - Section 106.1(d)(2).
Recent events (2)
  • — J (S)
  • — Z (S)

1910.22 A01

Serious Gravity 08 4 instances 11 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $720 · Current $200 Reduced
Recent events (2)
  • — J (S) $200.00
  • — Z (S) $720.00

1910.22 A02

Serious Gravity 09 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Dec 14, 1990
Penalty
Initial $810 · Current $400 Reduced
Recent events (2)
  • — J (S) $400.00
  • — Z (S) $810.00

1910.37 K02

Serious Gravity 09 4 instances 10 exposed
Issued
Nov 27, 1990
Abate by
Dec 7, 1990
Penalty
Initial $810 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $810.00

1910.106 E09 III

Serious Gravity 07 1 instance 3 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $630 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $630.00

1910.151 C

Serious Gravity 10 2 instances 3 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $900 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $900.00

1910.157 C04

Serious Gravity 07 1 instance 1 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $630 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $630.00

1910.157 E02

Serious Gravity 07 2 instances 5 exposed
Issued
Nov 27, 1990
Abate by
Dec 7, 1990
Penalty
Initial $630 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $630.00

1910.158 E02 III

Deleted Serious Gravity 08 6 instances 9 exposed
Issued
Nov 27, 1990
Abate by
Dec 7, 1990
Penalty
Initial $720
Recent events (2)
  • — J (S)
  • — Z (S) $720.00

1910.176 B

Serious Gravity 08 2 instances 8 exposed
Issued
Nov 27, 1990
Abate by
Dec 14, 1990
Penalty
Initial $720 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $720.00

1910.212 A05

Serious Gravity 08 1 instance 3 exposed
Issued
Nov 27, 1990
Abate by
Dec 17, 1990
Penalty
Initial $720 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $720.00

1910.303 B01

Serious Gravity 09 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $810 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $810.00

1910.303 F

Serious Gravity 07 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $630 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $630.00

1910.1200 E01

Serious Gravity 09 1 instance 26 exposed
Issued
Nov 27, 1990
Abate by
Dec 27, 1990
Penalty
Initial $810 · Current $200 Reduced
Recent events (2)
  • — J (S) $200.00
  • — Z (S) $810.00

1910.1200 F05

Serious Gravity 05 1 instance 3 exposed
Issued
Nov 27, 1990
Abate by
Dec 7, 1990
Penalty
Initial $450 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $450.00

1910.1200 G01

Serious Gravity 05 1 instance 3 exposed
Issued
Nov 27, 1990
Abate by
Dec 28, 1990
Penalty
Initial $450 · Current $100 Reduced
Recent events (2)
  • — J (S) $100.00
  • — Z (S) $450.00

1910.1200 H

Serious Gravity 09 1 instance 15 exposed
Issued
Nov 27, 1990
Abate by
Jan 25, 1991
Penalty
Initial $810 · Current $200 Reduced
Recent events (2)
  • — J (S) $200.00
  • — Z (S) $810.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Ground Floor, Left Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Ground Floor, Right Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 1, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 1, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 2, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 2, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 3, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 4, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 4, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 5, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 6, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 6, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 7, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 8, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #1, Floor - 8, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Ground Floor, Left Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Ground Floor, Right Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 1, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 1, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 2, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 2, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 3, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 3, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 4, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 4, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 5, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 5, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 6, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 7, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 7, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 8, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #2, Floor 8, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Ground Floor, Left Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Ground Floor, Right Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 1, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 1, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 2, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 2, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 3, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 3, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 4, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 4, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 5, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 5, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 6, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 6, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 7, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 7, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 8, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #3, Floor 8, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Ground Floor, Left Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Ground Floor, Right Door
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 1, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 1, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 2, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 3, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 3, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 4, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 4, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 5, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 5, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 6, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 6, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 7, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 7, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 8, Door - A
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

5(a)(1)

Willful Gravity 10 1 instance 10 exposed
Issued
Nov 27, 1990
Abate by
Nov 30, 1990
Penalty
Initial $9,000 · Current $4,375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or before June 1, 1990 to on or about July 16, 1990, employees
operating a freight elevator, and/or riding a freight elevator,
and/or working in the vicinity of a freight elevator were exposed
to the hazard of falling into the elevator shaft and/or being crushed
by the elevator cab.
a) Location: Elevator #4, Floor 8, Door - B
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to:
1) Equip each hoistway door with a hoistway door interlock device.
2) The interlock device shall hold the door in the locked position
by means of gravity or by a restrained compression spring, or by
both, or by means of a positive linkage.
3) The interlock shall lock the door in the closed position before
the elevator can be operated.
Reference Publication(s):
1) American National Standard Institute/American Society of Mechanical
Engineers A17.3 - 1986 "Safety Code for Existing Elevators and
Escalators", Section 2.7.1 - ANSI/ASME A17.1 - 1981, Section 111.1(b)
2) BOCA - Basic Building Code - Article 26, Section 2605.8.2.
Recent events (2)
  • — J (W) $4375.00
  • — Z (W) $9000.00

View Newark Refrigerated Warehouse, INC.'s full OSHA safety record →