NEW BEDFORD, MA —
OSHA Inspection: DICK CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DICK CORPORATION in 1000 SOUTH RODNEY FRENCH BOULEVARD, NEW BEDFORD, MA 02744 (NAICS 000000). OSHA activity number 109172387.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DICK CORPORATION
- Site address
- 1000 SOUTH RODNEY FRENCH BOULEVARD
- City
- NEW BEDFORD
- State
- MA
- ZIP
- 02744
- Mailing
- P.O. BOX 10896, PITTSBURGH, PA 15236
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1629
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 19, 1995
- Abate by
- Nov 22, 1995
- Penalty
- Initial $1,700 · Current $1,700
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)The hazard of entering the Effluent Structure a thirty-six feet deep, twenty feet diameter enclosed tank at New Bedford Waste Water Treatment Facility, where there was the potential for a hazardous atmosphere. Among other methods, one feasible and acceptable abatement to correct this hazard is to enforce an adequate Confined Space Entry Procedures meeting the stipulations of Dick corporations confined space entry program and/or NIOSH Criteria Document No. 80-106, December 1979 and/or ANSI Z117-1989 safety requirements for confined spaces. Elements of a confined space entry program which were not implemented when the Effluent Structured was entered include but are not limited to: 1)Implementing a permit system to certify that all existing hazards have been evaluated and necessary protective measures have been taken. 2)Atmospheric testing for oxygen deficiency, flammability, and toxic materials. 3)Providing quick and safe rescue of employees inside the confined space by the availability of safety equipment such as harness and lifeline. 4)Labeling the entrance to the confined space to ensure entry by permit only.
Recent events (2)
- — I (S) $1700.00
- — Z (S) $1700.00
1926.21 B06 I
- Issued
- Oct 19, 1995
- Abate by
- Nov 22, 1995
- Penalty
- Current $1,000
Recent events (2)
- — I (O) $1000.00
- — Z (S)
1926.103 E08
- Issued
- Oct 19, 1995
- Abate by
- Nov 22, 1995
Recent events (2)
- — I (O)
- — Z (S)
More inspections at Dick Corporation
View Dick Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 109172387.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.