Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARDANT ELECTRICAL CONSTRUCTION CO., INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MARDANT ELECTRICAL CONSTRUCTION CO., INC. in 245 STATE ROAD 312, ST AUGUSTINEE, FL 32095 (NAICS 000000). OSHA activity number 110092632.

Watch Mardant Electrical Construction CO., INC. — free Get an email when a new federal OSHA severe-injury report for Mardant Electrical Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
245 STATE ROAD 312
City
ST AUGUSTINEE
State
FL
ZIP
32095
Mailing
8967 PHILLIPS HIGHWAY, JACKSONVILLE, FL 32256
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
1
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $536.00 · Current $536.00
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did
not furnish employment and a place of employment which were free from
recognized
hazards that were causing or likely to cause death or serious physical
harm to employees
in that employees were exposed to a crushing injury:
a.At the job site on 245 State Road 312, employees were exposed to a
crushing injury if a slack condition on the fiber sling was created while
Derrick #Y80DVEB1369, was lifting parking lot light poles without a
"safety latch" on the hook.
Among other methods, one feasible and acceptable abatement method is
to make sure all hooks are equipped with a "safety latch" unless the
application makes the use of the latch impractical and to make sure the
"safety latch" always bridges the throat opening of the hook in the close
position.  As per American National Standard Institute, B30.5-1982,
Section 5-1.7.6. (Revision of USAS B30.5-1968).

1926.20 B01

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $516.00 · Current $516.00

1926.59 E01 I

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $500.00 · Current $500.00

1926.59 E02 III

Serious Gravity 02 1 instance 1 exposed
Issued
Abate by

1926.251 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $516.00 · Current $516.00

1926.251 C05

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $516.00 · Current $516.00

1926.251 C05

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by

1926.550 B02

Serious Gravity 03 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $516.00 · Current $516.00

View MARDANT ELECTRICAL CONSTRUCTION CO., INC.'s full OSHA safety record →

KGC, INC.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110092632.