Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: EASTERN COLORADO WELL SERVICE LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of EASTERN COLORADO WELL SERVICE LLC in NESE 34-16S-44W, CHEYENNE WELLS, CO 80810 (NAICS 213112). OSHA activity number 110484771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eastern Colorado Well Service LLC — free Get an email when a new federal OSHA severe-injury report for Eastern Colorado Well Service LLC is published. One employer, no account, unsubscribe in one click.
Site address
NESE 34-16S-44W
City
CHEYENNE WELLS
State
CO
ZIP
80810
Mailing
880 WEST HWY 40, CHEYENNE WELLS, CO 80810
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
4
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 03 1 instance 3 exposed
Issued
Sep 5, 2007
Abate by
Sep 12, 2007
Penalty
Initial $875 · Current $875
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to burns, falls, and explosion hazards due to the escape
system not being in place:
a)  On or about April 20, 2007 and at times prior, Eastern Colorado Well
Service LLC
did not ensure that employees were protected from fall, fire, and
explosion hazards due
to the geronimo line not being installed at the monkeyboard.
One feasible and acceptable method of abatement would be to train the
crews to inspect and
properly install the excape device before begining well servicing
activities.
Abatement Note:  Abatement certification and documentation is required for
this item (see
enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
  • — I (S) $875.00
  • — Z (S) $875.00

5(a)(1)

Serious Gravity 10 6 instances 2 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Penalty
Initial $2,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to struck-by and crushing hazards from falling derricks or
rotating tongs which
were improperly connected to their wire rope anchor/guy lines:
a)  On or about April 20, 2007 and at times prior, Eastern Colorado Well
Service LLC
did not ensure that employees were protected from struck-by and crushing
hazards.
1.  Crosby clips were not used correctly in that the "U" section was
placed in
contact with the live end of the wire rope, thus crushing and stressing
the wire
strands.
2.  Crosby clips were not used correctly in that the correct number and
spacing
for the size of wire rope according to ASME B30.9 was not followed.
3.  Thimbles were not used at points of connection leaving wire rope to
spreading
apart and abuse to individual wire strands.
4.  Job built anchor clamping devices were not tested to ensure they
conform to
manufacturers specifications on rig anchorage.  The slots for the chain to
connect
to is not uniform in size and placement.  The "U" section of the crosby
clamps
used is stressing the wire rope.
5.  Load boomers were used to tighten the wire rope cables for the rig and
then
were left with the tension of the line intact.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is
to follow wire rope manufacturers recommendations Ref: ASME B30.9.  Job
built clamping
devices and unrated devices should not be allowed to be used as part of
the anchoring process
unless they are tested and rated to accepted engineering standards.
Abatement Note:  Abatement certification and documentation is required for
this item (see
enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2500.00

1910.27 D01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Penalty
Initial $2,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2500.00

1910.184 D

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Penalty
Initial $2,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2500.00

1910.184 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Recent events (2)
  • — I (S)
  • — Z (S)

1910.184 E02 I

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Recent events (2)
  • — I (S)
  • — Z (S)

1910.184 E03 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 5, 2007
Abate by
Dec 14, 2007
Recent events (2)
  • — I (S)
  • — Z (S)

View Eastern Colorado Well Service LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110484771.