SAIPAN, MP —
OSHA Inspection: US-CNMI DEVELOPMENT CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of US-CNMI DEVELOPMENT CORPORATION in CHALAN KIYA AT BOTTOM OF HILL TO COLLEGE, SAIPAN, MP 96950 (NAICS 000000). OSHA activity number 110528197.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US-CNMI DEVELOPMENT CORPORATION
- Site address
- CHALAN KIYA AT BOTTOM OF HILL TO COLLEGE
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- P.O. BOX 10001 PMB-A47, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2331
- Employees
- 325
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.215 A04
- Issued
- Nov 16, 2001
- Abate by
- Dec 6, 2001
- Penalty
- Initial $1,625 · Current $813 Reduced
Recent events (2)
- — I (S) $812.50
- — Z (S) $1625.00
1910.215 B09
- Issued
- Nov 16, 2001
- Abate by
- Dec 6, 2001
Recent events (2)
- — I (S)
- — Z (S)
1910.212 A03 II
- Issued
- Nov 16, 2001
- Abate by
- Nov 29, 2001
- Penalty
- Initial $2,275 · Current $1,138 Reduced
Recent events (2)
- — I (S) $1137.50
- — Z (S) $2275.00
5(a)(1)
- Issued
- Nov 16, 2001
- Abate by
- Dec 6, 2001
- Penalty
- Initial $1,875 · Current $938 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards due to the absence of a hoistway-door locking device: a)The hoist to the Sewing Department on the 2nd and 3rd floor does not have a hoistway- door locking device to prevent operation if the door is open, and to prevent opening of the door unless the hoist is at the landing. The absence of a hoistway-door locking device places employees at risk of becoming crushed between the hoist and the ground floor, and at risk of falling into the shaft, resulting in broken bones or amputations. One feasible method of correcting this hazard is to install a hoistway-door combination mechanical lock and electrical contact or a hoistway-door interlock as referenced in ASME A17.1, Part I, Hoistways, Hoistway Enclosures, and Related Construction for Hand and Power Passenger and Freight Elevators and Dumbwaiters.
Recent events (2)
- — I (S) $937.50
- — Z (S) $1875.00
More inspections at Us-Cnmi Development Corporation
View Us-Cnmi Development Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 110528197.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.