CLAIRINGTON, OH —
OSHA Inspection: DEMAND COMMUNICATIONS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEMAND COMMUNICATIONS, INC in 46550 KURTZMAN RD TH.2234, CLAIRINGTON, OH 43915 (NAICS 000000). OSHA activity number 112539838.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEMAND COMMUNICATIONS, INC
- Site address
- 46550 KURTZMAN RD TH.2234
- City
- CLAIRINGTON
- State
- OH
- ZIP
- 43915
- Mailing
- 54 CENTRAL AVE, OWEGO, NY 13827
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 22, 1999
- Abate by
- Dec 2, 1999
- Penalty
- Initial $2,000 · Current $1,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: At Altel's worksite in Clarington, Ohio, the employer did not ensure that his employee who was disconnecting the crane attachment from the tower was protected from a fall hazard while ascending and descending the tower at height in excess of 55 feet above the ground. Among other methods, feasible and accepted abatement methods to correct the hazardous condition may include: 1. Utilize approved aerial lifts, where possible, in accordance with 29 CFR 1926.453. 2. Utilize approved safety climbing devices and fall arrest systems while climbing the tower. 3. Require employees to use two lanyards leaving at least one connected at all times. 4. Install vertical life line on tower components prior to erection.
Recent events (2)
- — F (S) $1250.00
- — Z (S) $2000.00
More inspections at Demand Communications, INC
View Demand Communications, INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 112539838.