ALPOCA, WV —
OSHA Inspection: TALON MANUFACTURING CO. INC. PLANT #7
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of TALON MANUFACTURING CO. INC. PLANT #7 in WV RT.#10, ALPOCA, WV 24710 (NAICS 000000). OSHA activity number 116516980.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TALON MANUFACTURING CO. INC. PLANT #7
- Site address
- WV RT.#10
- City
- ALPOCA
- State
- WV
- ZIP
- 24710
- Mailing
- 621 W. KING STREET, MARTINSBURG, WV 25401
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3999
- Employees
- 53
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- May 6, 1997
- Abate by
- May 30, 1997
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer failed to implement engineering controls necessary to prevent overheating of the solution used to destroy the detonators, thereby exposing employees to explosion hazards: (a)Talon Manufacturing Company, Inc., Plant #7, Lower Alpoca, Demilitarization Procedure for Detonators. The company failed to provide continuous agitation of the solution used to destroy the detonators which would have prevented the solution from overheating. The company also failed to install temperature monitors and temperature controls on the destruction process. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: a.Install agitators on the vessel which contains the solution used to destroy the detonators to prevent localized overheating of the solution. b.Install a continuous temperature monitor with an alarm which indicates that the temperature of the solution is beginning to rise along with a temperature control system that would safely shut down the operation prior to a critical temperature being reached.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $7000.00
5(a)(1)
- Issued
- May 6, 1997
- Abate by
- May 30, 1997
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer failed to control possible sources of static electricity thereby exposing employees to explosion hazards: (a)Talon Manufacturing Company Inc., Plant #7, Lower Alpoca, Demilitarization Procedure for Detonators. The employer was using non-conductive plastic, 55 gallon drums as process vessels for the chemical destruction of detonators and leads, which contained tetryl and or lead azide explosives with no means to ground the vessels and prevent the accumulation of static electricity on the surface of the drum. There was the potential for the formation of hydrogen gas on the surface of the solution in the detonator destruction drum which could ignite from a static spark. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: a.Prohibit the use of nonconductive plastic drums unless they are used with proper grounding or bonding techniques.ve
Recent events (2)
- — I (S) $3500.00
- — Z (S) $7000.00
5(a)(1)
- Issued
- May 6, 1997
- Abate by
- May 15, 1997
- Penalty
- Initial $7,000 · Current $3,500 Reduced
24102260S113P108
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer failed to prevent the contamination of the solution (used to destroy the detonators) with incompatible metals such as copper, iron and mercury thereby exposing employees to an explosion hazard: (a) Talon Manufacturing Company Inc., Plant #7, Lower Alpoca, Demilitarization Procedure for Detonators. The same bucket was being used to drain the propyl glycol solution from the detonators and leads thereby allowing the solution used to destroy the detonators to become contaminated with brass from the casings on the leads. The brass could react in this solution and form copper azide. (b)Talon Manufacturing Company Inc., Plant #7, Lower Alpoca, Demilitarization Procedures for Detonators. The water used in the detonation solution was from a local well and no quality control tests were conducted on the water to assure that it was not contaminated with iron, copper or mercury which could form highly sensitive explosive azide salts. (c)Talon Manufacturing Company Inc., Plant #7, Lower Alpoca, Demilitarization Procedures for Detonators. An iron spade was also being used to stir the solution which could contaminate it with iron. (d)Talon Manufacturing Company Inc., Plant #7, Lower Alpoca, Demilitarization Procedures for Detonators. A glass mercury thermometer was being used to measure the solution temperature in the new process building on 12/3/96. Accidental breakage of the thermometer in the azide solution could produce mercury azide, a highly sensitive explosive compound. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: a.Use separate buckets in the recovery of leads and detonators from the glycol solution. b.Establish strict quality control on the water used in the destruction solutions and the glycol solutions. c.Prohibit the use of iron or steel tools in the destruction solutions. d.Prohibit the use of glass mercury thermometers in the azide solutions.
Recent events (2)
- — I (S) $3500.00
- — Z (S) $7000.00
1910.37 A
- Issued
- May 6, 1997
- Abate by
- May 30, 1997
- Penalty
- Initial $5,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $5000.00
1910.151 C
- Issued
- May 6, 1997
- Abate by
- Jun 20, 1997
- Penalty
- Initial $5,000 · Current $2,500 Reduced
22602410S113
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
1910.1200 F05 I
- Issued
- May 6, 1997
- Abate by
- May 15, 1997
- Penalty
- Initial $5,000 · Current $2,500 Reduced
2260S113
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
1910.1200 F05 II
- Issued
- May 6, 1997
- Abate by
- May 15, 1997
2260S113
1910.141 D02 II
- Issued
- May 6, 1997
- Abate by
- Jun 20, 1997
24102260S113
More inspections at Talon Manufacturing CO. INC. Plant #7
View Talon Manufacturing CO. INC. Plant #7's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 116516980.