IRONTON, OH —
OSHA Inspection: ALLIED SIGNAL CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALLIED SIGNAL CORP. in 3330 S. THIRD STREET, IRONTON, OH 45638 (NAICS 000000). OSHA activity number 121984165.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLIED SIGNAL CORP.
- Site address
- 3330 S. THIRD STREET
- City
- IRONTON
- State
- OH
- ZIP
- 45638
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2865
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 20, 1999
- Abate by
- May 25, 1999
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a)Fire and explosion from the release of combustible liquid vapors from tank #8, in that the tank and all tank appurtenances, including, but not limited to, emergency vents (including venting to a safe location) sample valves and dip holes were not properly inspected and maintained to ensure that they function as intended, such as, but not limited to the following: 1)The sample valve (run off) was corroded and failed at its thread section. 2)The emergency vent hatch was prevented from opening as designed because of a catwalk extension installed over the hatch. In addition, the openings on top of the tank was not designed to vent to a safe location. 3)The dip hole cover at the top of the tank was not of the self-closing type, nor was it of the liquid tight design. Among other methods, feasible and acceptable abatement methods to abate these hazards would include development and implementation of a program to inspect, test and maintain the quality and integrity of all critical equipment associated with processing tanks including safe venting locations in accordance with recognized industry practices, such as the American Petroleum Institute (API 750), NFPA 30 Code for Flammable and Combustible liquids and OSHA's Process Safety Management Standard 29 CFR 1910.119.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $7000.00
More inspections at Allied Signal Corp.
View Allied Signal Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 121984165.