OSHA Inspection: ACCELLENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACCELLENT in 200 WEST 7TH AVENUE, COLLEGEVILLE, PA 19426 (NAICS 000000). OSHA activity number 123263535.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accellent — free Get an email when a new federal OSHA severe-injury report for Accellent is published. One employer, no account, unsubscribe in one click.
Establishment
ACCELLENT
Site address
200 WEST 7TH AVENUE
City
COLLEGEVILLE
State
PA
ZIP
19426
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3498
Employees
340
Ownership type
A
Industry flags
Manufacturing safety.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 4 exposed
Issued
May 4, 1994
Abate by
May 9, 1994
Penalty
Initial $1,800 · Current $1,080 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to falling load due to failure of wire rope and
the lack of markings
on the pendant controls:
a) Furnace Area - Employees operated a Electro Lift Shaw box 1 ton hoist
with two
parts of line on an underhung crane .  The wire rope on the hoist was
severely
damaged.  The rope showed numerous broken wires on the rope from the
dead-end
connection to the load block when set on the floor.  Numerous broken
wires were
noted in one lay of rope with 6 to 8 breaks in one strand in that lay.
b) Degreaser area - Pendant controls were not marked on the Cleveland
Tramrail
overhead underhung crane.
c) 6200 Department - Pendant controls were not marked on the on the
electro lift one
ton overhead underhung crane.
ABATEMENT NOTE: Among others one feasible and acceptable abatement method
is to
replace the wire rope on the crane and to establish an inspection program
by a competent
person for all underhung cranes based on the criteria set forth in
American National
Standards Institute (ANSI) B30.11 Monorail Systems and Underhung Cranes,
latest edition.
Recent events (2)
  • — I (S) $1080.00
  • — Z (S) $1800.00

1910.305 G02 III

Serious Gravity 01 3 instances 1 exposed
Issued
May 4, 1994
Abate by
May 9, 1994
Penalty
Initial $1,350 · Current $810 Reduced
Recent events (2)
  • — I (S) $810.00
  • — Z (S) $1350.00

1910.303 B01

Serious Gravity 01 1 instance 25 exposed
Issued
May 4, 1994
Abate by
May 9, 1994
Penalty
Initial $1,350 · Current $810 Reduced
Recent events (2)
  • — I (S) $810.00
  • — Z (S) $1350.00

1910.212 A01

Serious Gravity 01 1 instance 5 exposed
Issued
May 4, 1994
Abate by
Mar 17, 1995
Penalty
Initial $1,350 · Current $810 Reduced
Recent events (3)
  • — P (S) $810.00
  • — I (S) $810.00
  • — Z (S) $1350.00

View Accellent's full OSHA safety record →