AKUTAN, AK —
OSHA Inspection: TRIDENT SEAFOODS CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRIDENT SEAFOODS CORPORATION in M/V SEA ALASKA-AKUTAN, AKUTAN, AK 99553 (NAICS 000000). OSHA activity number 301494530.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRIDENT SEAFOODS CORPORATION
- Site address
- M/V SEA ALASKA-AKUTAN
- City
- AKUTAN
- State
- AK
- ZIP
- 99553
- Mailing
- 5011 JEWEL LAKE ROAD #203, ANCHORAGE, AK 99502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 140
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 10, 1998
- Abate by
- Jul 22, 1998
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Action of 1979: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the potential hazard of electrical burns while using a duplex outlet having reversed polarity as a power source for tools and extension cords: (a)M/V Sea Alaska: A duplex receptacle attached to the front of a workbench located on the port side of the upper water maker indicated reversed polarity when tested with the Ideal Circuit Tester 61-035. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have a qualified/certified electrician to repair the unit by reversing the wiring connections on the receptacle terminals.
Recent events (2)
- — I (S) $637.50
- — Z (S) $1275.00
5(a)(1)
- Issued
- Jul 10, 1998
- Abate by
- Jul 22, 1998
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical burns while using portable power tools which contained service cords with cracked and damaged outer insulation and missing ground pin: (a)M/V Sea Alaska: A portable drill was so covered with paint that proper identification, to include whether or not it was a double insulated type tool, could not be determined and a replacement plug, on the service cord, had a broken ground pin. (b)M/V Sea Alaska: A portable bandsaw (S/N 0457261154) contained cracked/damaged outer insulation. (c)M/V Sea Alaska: A portable circular saw (S/N 546795455) contained cracked/damaged outer insulation. Among other methods, one feasible and acceptable method to correct these hazards is to replace the damaged service cords and plugs, on all effected power tools, before use.
Recent events (2)
- — I (S) $637.50
- — Z (S) $1275.00
5(a)(1)
- Issued
- Jul 10, 1998
- Abate by
- Jul 22, 1998
- Penalty
- Initial $2,125 · Current $1,063 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burns and or electrocution: (a)M/V Sea Alaska: A 220 volt electrical power panel, number B-8, located in the engine room welding shop, contained a 3 inch by 2-1/2 inch wide unused opening which revealed exposed live electrical parts, in the circuit breaker cover plate. Among other methods, one feasible and acceptable abatement method to correct this hazard is to insert an approved snap in type cover plate into the hole.
Recent events (2)
- — I (S) $1062.50
- — Z (S) $2125.00
More inspections at Trident Seafoods Corporation
View Trident Seafoods Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301494530.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.