Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN SEAFOODS COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN SEAFOODS COMPANY in F/T NORTHERN HAWK, NAKNEK, AK 99633 (NAICS 000000). OSHA activity number 301494910.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Seafoods Company — free Get an email when a new federal OSHA severe-injury report for American Seafoods Company is published. One employer, no account, unsubscribe in one click.
Site address
F/T NORTHERN HAWK
City
NAKNEK
State
AK
ZIP
99633
Mailing
2025 FIRST AVENUE, SUITE 9, SEATTLE, WA 98121
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2092
Employees
153
Ownership type
A
Industry flags
Maritime safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 5 instances 1 exposed
Issued
Oct 15, 1998
Abate by
Nov 17, 1998
Penalty
Initial $2,125 · Current $1,063 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of electrical shock, burns and/or electrocution
where exposure to the
potential use of ungrounded or defective portable power tools and/or the
use of appliances in
wet/damp locations are used in combination with incorrectly wired
electrical outlets and/or
receptacles without a GFCI.  The following conditions contributed to the
existence of these
hazards:
(a)F/T Northern Hawk - On the port side of the upper engine room, two
receptacles
indicated reverse when tested with IDEAL circuit tester #61-035.
(b)F/T Northern Hawk - In the upper engine room, one receptacle indicated
a short
circuit when tested.
(c)F/T Northern Hawk - In the galley area, a receptacle at the rinse sink
and a
receptacle over the countertop at the rear portion of the galley indicated
reverse
polarity when tested and neither receptacle was suitable for the location
as they
were not of the GFCI type.
(d)F/T Northern Hawk - In suite #330, the receptacle located over the desk
indicated
a short circuit when tested.
Recent events (2)
  • — I (S) $1062.50
  • — Z (S) $2125.00

5(a)(1)

Serious Gravity 01 2 instances 1 exposed
Issued
Oct 15, 1998
Abate by
Oct 21, 1998
Penalty
Initial $1,275 · Current $638 Reduced
5(a)(1) of the Occupational Safety and Health Act of 1970: The employer
did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or were likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of electrical shock, burns or trauma where
exposure to the potential
use of ungrounded appliances in areas that are wet or damp could occur.
The following
conditions contributed to the existence of these hazards:
(a)F/T Northern Hawk, in the engine room - A portable quartz light fixture
had a
damaged/defective service cord. The plug was missing its ground pin and
the cord
conductors appear to have been spliced and the splice was wrapped with blue
tape. The employer failed to attach a "Danger Do Not Use Tag" and/or
failed to
remove the damaged/defective fixture from service until proper repairs
could be
made.
(b)F/T Northern Hawk, in the engine room - Where an extension cord used as
a
power source for the graymil mineral spirits vat contained damage to the
outer
insulation at the connector which prevented proper strain relief of the
conductors
at the connectors terminals, the employer failed to remove the
damaged/defective
extension cord from service until proper repairs could be made.
Recent events (2)
  • — I (S) $637.50
  • — Z (S) $1275.00

1910.106 E09 III

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Oct 15, 1998
Abate by
Oct 23, 1998
Recent events (2)
  • — I (O)
  • — Z (O)

View American Seafoods Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 301494910.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.