NAKNEK, AK —
OSHA Inspection: AMERICAN SEAFOODS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN SEAFOODS COMPANY in F/T NORTHERN HAWK, NAKNEK, AK 99633 (NAICS 000000). OSHA activity number 301494910.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN SEAFOODS COMPANY
- Site address
- F/T NORTHERN HAWK
- City
- NAKNEK
- State
- AK
- ZIP
- 99633
- Mailing
- 2025 FIRST AVENUE, SUITE 9, SEATTLE, WA 98121
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 153
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 15, 1998
- Abate by
- Nov 17, 1998
- Penalty
- Initial $2,125 · Current $1,063 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burns and/or electrocution where exposure to the potential use of ungrounded or defective portable power tools and/or the use of appliances in wet/damp locations are used in combination with incorrectly wired electrical outlets and/or receptacles without a GFCI. The following conditions contributed to the existence of these hazards: (a)F/T Northern Hawk - On the port side of the upper engine room, two receptacles indicated reverse when tested with IDEAL circuit tester #61-035. (b)F/T Northern Hawk - In the upper engine room, one receptacle indicated a short circuit when tested. (c)F/T Northern Hawk - In the galley area, a receptacle at the rinse sink and a receptacle over the countertop at the rear portion of the galley indicated reverse polarity when tested and neither receptacle was suitable for the location as they were not of the GFCI type. (d)F/T Northern Hawk - In suite #330, the receptacle located over the desk indicated a short circuit when tested.
Recent events (2)
- — I (S) $1062.50
- — Z (S) $2125.00
5(a)(1)
- Issued
- Oct 15, 1998
- Abate by
- Oct 21, 1998
- Penalty
- Initial $1,275 · Current $638 Reduced
General-duty citation text
5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock, burns or trauma where exposure to the potential use of ungrounded appliances in areas that are wet or damp could occur. The following conditions contributed to the existence of these hazards: (a)F/T Northern Hawk, in the engine room - A portable quartz light fixture had a damaged/defective service cord. The plug was missing its ground pin and the cord conductors appear to have been spliced and the splice was wrapped with blue tape. The employer failed to attach a "Danger Do Not Use Tag" and/or failed to remove the damaged/defective fixture from service until proper repairs could be made. (b)F/T Northern Hawk, in the engine room - Where an extension cord used as a power source for the graymil mineral spirits vat contained damage to the outer insulation at the connector which prevented proper strain relief of the conductors at the connectors terminals, the employer failed to remove the damaged/defective extension cord from service until proper repairs could be made.
Recent events (2)
- — I (S) $637.50
- — Z (S) $1275.00
1910.106 E09 III
- Issued
- Oct 15, 1998
- Abate by
- Oct 23, 1998
Recent events (2)
- — I (O)
- — Z (O)
More inspections at American Seafoods Company
View American Seafoods Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)