NAKNEK, AK ·
OSHA Inspection: SNOPAC PRODUCTS INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SNOPAC PRODUCTS INC in M/V SNOPAC-NAKNEK, NAKNEK, AK 99633 (NAICS 000000). OSHA activity number 301495677.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SNOPAC PRODUCTS INC
- Site address
- M/V SNOPAC-NAKNEK
- City
- NAKNEK
- State
- AK
- ZIP
- 99633
- Mailing
- 5053 EAST MARGINAL WAY SOUTH, SEATTLE, WA 98134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 101
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 17, 1999
- Abate by
- Jan 14, 2000
- Penalty
- Initial $1,300 · Current $650 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause serious physical harm to employees in that employees were exposed to the hazard of amputation and/or severe laceration during blade changes and cleaning operations involving header and gulleter machines from accidental start-up reactivation: F/V Snopac, processing area - Where engineering/processing personnel were required to clean and maintain each of the header and gulleter machines at this location, workers exposed themselves to the hazard of severe laceration and/or amputation from contact with sharpened blades energized by electrical and pneumatic sources. The energy isolation program in place consisted only of generic verbiage and did not direct the user of the procedure with specific steps for shutting down and isolating equipment nor did it cover the placement, removal, and transfer of lockout/tagout devices; machine specific procedures were not developed for testing verifying the effectiveness of these devices and other control measures such as pressure bleed and valving. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard would be to develop and implement equipment specific lockout/tagout procedures for these machines
Recent events (2)
- · I (S) $650.00
- · Z (S) $1300.00
5(a)(1)
- Issued
- Dec 17, 1999
- Abate by
- Dec 30, 1999
- Penalty
- Initial $1,300 · Current $1,300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause physical harm to employees in that employees were exposed to inhalation as well as fire/explosion hazards as a result of severe corrosion on the manifold assembly of stored ammonia cylinders and the potential for these pressurized cylinders to leak: F/V Snopac, deck storage area - Where ammonia cylinders were stored in such a manner that they were exposed to the effects of weather and salt water, the manifold of one of the cylinders (full) was severely corroded and posed the potential for the contents to leak; a leaking cylinder in this location would have created an inhalation hazard to personnel in the vicinity of the cylinder as well as a reentrainment hazard to occupied spaces within the vessel. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazardous condition would be to store anhydrous ammonia cylinders in a protected location and inspect these cylinders periodically (for instance quarterly) for indications of corrosion.s
Recent events (2)
- · I (S) $1300.00
- · Z (S) $1300.00
1910.95 D01
- Issued
- Dec 17, 1999
- Abate by
- Feb 7, 2000
- Penalty
- Initial $1,300 · Current $1,300
Recent events (2)
- · I (S) $1300.00
- · Z (S) $1300.00
1910.134 H03 IA
- Issued
- Dec 17, 1999
- Abate by
- Dec 30, 1999
- Penalty
- Initial $975 · Current $975
Recent events (2)
- · I (S) $975.00
- · Z (S) $975.00
1910.151 C
- Issued
- Dec 17, 1999
- Abate by
- Dec 30, 1999
- Penalty
- Initial $975 · Current $975
Recent events (2)
- · I (S) $975.00
- · Z (S) $975.00
1910.132 D02
- Issued
- Dec 17, 1999
- Abate by
- Feb 7, 2000
Recent events (2)
- · I (O)
- · Z (O)
1915.152 B
- Issued
- Dec 17, 1999
- Abate by
- Feb 7, 2000
Recent events (2)
- · I (O)
- · Z (O)
1910.169 B03 IV
- Issued
- Dec 17, 1999
- Abate by
- Jan 14, 2000
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 F05 I
- Issued
- Dec 17, 1999
- Abate by
- Dec 30, 1999
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 F05 II
- Issued
- Dec 17, 1999
- Abate by
- Dec 30, 1999
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Snopac Products INC
View Snopac Products INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 301495677.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.