BRYCELAND, LA ·
OSHA Inspection: CUDD PRESSURE CONTROL, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of CUDD PRESSURE CONTROL, INC. in OTTO CUMMINGS NO.2 ALTERNATE WELL, BRYCELAND, LA 71014 (NAICS 000000). OSHA activity number 301994315.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUDD PRESSURE CONTROL, INC.
- Site address
- OTTO CUMMINGS NO.2 ALTERNATE WELL
- City
- BRYCELAND
- State
- LA
- ZIP
- 71014
- Mailing
- 4334 NW EXPY, STE 124, OKLAHOMA CITY, OK 73116
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 5
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 21, 1999
- Abate by
- May 17, 1999
- Penalty
- Initial $70,000 · Current $49,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the uncontrolled release of high pressure gas (i.e. blowout), fire and/or explosion. Otto Cummings No.2 ALT well, Sec 24-T17N-R7W, Bienville Parish, LA. On or about October 24, 1998, the employer did not ensure that the completion string and unsupported length of pipe could withstand the forces imposed upon it. Among other methods, one feasible and acceptable method to correct this hazard is to: 1. Design the completion string in such a way as to reduce the forces imposed upon it.
Recent events (2)
- · J (W) $49000.00
- · Z (W) $70000.00
1910.36 B01
- Issued
- Apr 21, 1999
- Abate by
- May 17, 1999
- Penalty
- Initial $55,000 · Current $38,500 Reduced
Recent events (2)
- · J (W) $38500.00
- · Z (W) $55000.00
More inspections at Cudd Pressure Control, INC.
View Cudd Pressure Control, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 301994315.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.