HOBOKEN, NJ —
OSHA Inspection: ST. MARY'S HOSPITAL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ST. MARY'S HOSPITAL in 308 WILLOW AVENUE, HOBOKEN, NJ 07030 (NAICS 000000). OSHA activity number 302127428.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ST. MARY'S HOSPITAL
- Site address
- 308 WILLOW AVENUE
- City
- HOBOKEN
- State
- NJ
- ZIP
- 07030
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8062
- Employees
- 970
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1030 D03 I
- Issued
- Oct 13, 1998
- Abate by
- Oct 23, 1998
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
5(a)(1)
- Issued
- Oct 13, 1998
- Abate by
- Dec 1, 1998
- Penalty
- Initial $17,500 · Current $10,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: the hazard of being infected with Mycobacterium tuberculosis through patient contact and special procedures such as aerosolized pentamidine treatment, bronchoscopy, suction procedures, and sputum induction. On or about 7/14/98 and 7/17/98 on the First Floor and Fifth and Sixth Floors, North: a) Nurses, nurse's aides, respiratory therapists, transporters, social workers, phlebotomist, doctors, and housekeeping personnel were exposed to the hazard of being infected with Mycobacterium tuberculosis through repeated and prolonged contact with active or suspect tuberculosis patients that occupied rooms not provided with negative pressure. Including, but not limited to: Family Practice Center (Exam Room #3), Respiratory Therapy Department- 1st floor; Rooms 627, 628 - 6th floor; Rooms 527, 528 - 5th floor. Among other methods, some feasible and acceptable abatement methods to correct this hazard as recommended by the CDC guidelines are: 1. Rooms occupied by TB or suspected TB patients must be under negative pressure exhausted to the outside and away from intake vents. 2. Screen patients suspected of having TB so that active TB patients may be quickly placed in AFB isolation. Provide a rapid diagnostic service. 3. Provide training to employees on the hazard and control of tuberculosis. The training must include the epidemiology, transmission and pathogenesis of tuberculosis. ABATEMENT NOTE: Once rooms have been certified as being under negative pressure, the following steps should be taken to ensure that condition: 1 Periodic checks are required to ensure that the desired negative pressure is present and that the continuous monitoring devices, if used, are properly maintained. 2. If smoke tubes or other visual checks are used, TB isolation rooms and treatment rooms should be checked frequently for negative pressure. 3. TB isolation rooms should be checked daily for negative pressure while being used for TB isolation. Reference:CDC MMWR October 28, 1994/Vol 43 Guidelines for preventing the Transmission of Tuberculosis in Health Care Settings with Special Focus on HIV Related Issues Violation observed on or about 7/14/98 and 7/17/98.St. Mary's Hospital was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent 5(a)(1) for failure to maintain negative pressure in the following rooms: Family Practice Center, #627, #628, #527, and #528. The citations were contained in OSHA Inspection Number 107199150, Citation Number 1, Item Number 1, issued on 7/25/96 and became final order on 8/15/96.
Recent events (2)
- — I (R) $10500.00
- — Z (R) $17500.00
1904.2 A
- Issued
- Oct 13, 1998
- Abate by
- Dec 1, 1998
Recent events (2)
- — I (O)
- — Z (O)
1910.1047 D07 I
- Issued
- Oct 13, 1998
- Abate by
- Oct 19, 1998
More inspections at ST. Mary'S Hospital
View ST. Mary'S Hospital's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302127428.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.