Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PUBLIC SERVICE ELECTRIC AND GAS COMPANY

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of PUBLIC SERVICE ELECTRIC AND GAS COMPANY in 905 MURRAY ROAD, EAST HANOVER, NJ 07936 (NAICS 000000). OSHA activity number 302132204.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Public Service Electric and GAS Company — free Get an email when a new federal OSHA severe-injury report for Public Service Electric and GAS Company is published. One employer, no account, unsubscribe in one click.
Site address
905 MURRAY ROAD
City
EAST HANOVER
State
NJ
ZIP
07936
Mailing
48 MIDDLE AVENUE, SUMMIT, NJ 07901
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
9631
Employees
76
Ownership type
A
Industry flags
Manufacturing health.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 1, 1999
Abate by
Apr 13, 1999
Penalty
Initial $4,500 · Current $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely to
cause death or serious
physical harm to the employee in that he was exposed to a fall hazard.
a) Warehouse, Tri Coastal Design, 905 Murray Road, East Hanover, NJ 07936
A PSE&G employee was raised on a pallet by a forklift truck approximately
12-13 feet to
monitor the carbon monoxide levels generated by two ceiling mounted gas
powered heaters. The
PSE&G employee did not use an appropriate safety platform and was exposed
to the hazard of
falling 12-13 feet to the concrete floor as fall protection was not
provided.
Violation occurred on or about 03/19/99.
Abatement Notes: Among others, one suitable method for abating this
hazardous condition is 1)
Utilize only platforms designed for use in elevating personnel with
forklifts. These platforms
must meet the requirements set forth in ANSI/ASME B56.1-1993. 2) Train all
employees about
the hazards of falls associated with improper elevating methods, and the
proper application and
use of safety platforms.
This violation requires both certification and documentation as
appropriate proof of abatement.