ENGLEWOOD, CO ·
OSHA Inspection: FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO in 2840 SOUTH ZUNI ST., ENGLEWOOD, CO 80110 (NAICS 000000). OSHA activity number 302306048.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULL SERVICE BEVERAGE DBA 7UP BOTTLING GROUP OF CO
- Site address
- 2840 SOUTH ZUNI ST.
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2086
- Employees
- 290
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
19 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 25, 1998
- Abate by
- Jan 28, 1999
- Penalty
- Initial $2,250 · Current $800 Reduced
0170
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees performing maintenance on and working in the vicinity of the Vilter Vaporiter were exposed to a potential ammonia release due to deterioration of the vessel walls. a) Among other methods, one feasible and acceptable abatement method to correct this hazard is to perform a non-destructive test such as ultrasonic thickness, ensuring minimal vessel wall thickness is maintained and incorporate such testing into a preventative maintenance schedule. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter")t-Certification
Recent events (2)
- · I (S) $800.00
- · Z (S) $2250.00
1910.37 F01
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $2,250 · Current $800 Reduced
Recent events (2)
- · I (S) $800.00
- · Z (S) $2250.00
1910.37 F06
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.38 A05 III
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $1,800 · Current $650 Reduced
Recent events (2)
- · I (S) $650.00
- · Z (S) $1800.00
1910.95 C01
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $4,500 · Current $1,500 Reduced
8110
Recent events (2)
- · I (S) $1500.00
- · Z (S) $4500.00
1910.95 K03 I
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
8110
Recent events (2)
- · I (S)
- · Z (S)
1910.95 K03 II
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
8110
Recent events (2)
- · I (S)
- · Z (S)
1910.95 K03 III
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
8110
Recent events (2)
- · I (S)
- · Z (S)
1910.120 Q02
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $4,500 · Current $1,500 Reduced
Recent events (2)
- · I (S) $1500.00
- · Z (S) $4500.00
1910.120 Q03 IV
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.120 Q06
- Issued
- Nov 25, 1998
- Abate by
- Jan 2, 1999
Recent events (2)
- · I (S)
- · Z (S)
1910.146 C02
- Issued
- Nov 25, 1998
- Abate by
- Jan 2, 1999
- Penalty
- Initial $2,250 · Current $800 Reduced
Recent events (2)
- · I (S) $800.00
- · Z (S) $2250.00
1910.146 C03
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.151 C
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $1,800 · Current $650 Reduced
Recent events (2)
- · I (S) $650.00
- · Z (S) $1800.00
1910.1200 E01
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
- Penalty
- Initial $3,150 · Current $1,100 Reduced
Recent events (2)
- · I (S) $1100.00
- · Z (S) $3150.00
1910.1200 F05 I
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 F05 II
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 H
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (S)
- · Z (S)
1910.134 E01
- Issued
- Nov 25, 1998
- Abate by
- Dec 28, 1998
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Full Service Beverage DBA 7UP Bottling Group of CO
View Full Service Beverage DBA 7UP Bottling Group of CO's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302306048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.